22
Cleaning
What?
How often?
Using what?
inside of stove
at least 1 x per year
hand brush,
vacuum cleaner
connection piece
at least 1 x per year
hand brush,
vacuum cleaner
glass panel
as required
when cold
using glass cleaner for
stoves- and oven glasses
Water pipes
The water pipes in the upper combustion chamber
should be cleaned on a regular basis. The cleaning in-
terval will depend on the level of soiling.
● Remove the deflector plate from the combustion
chamber.
● Unscrew the insulating flap above the combustion
chamber opening (2 wing nut, Fig. 7).
●
Unscrew the inspection hatch (6 nuts).
●
Take out the separating wall water-heat exchanger
(Fig. 5).
●
Take out the 2 horizontal heat exchanger sheet met-
al elements (Fig. 6).
●
The device should be cleaned using the wire brush
provided.
Fig. 5 Separating wall water-heat exchanger
Fig. 6
Heat exchanger sheet metal elements