background image

Königshütte 

Lima 2.0  6 kW

Pellet stove

GB

Installation instructions

for the specialist company

Minimum distances from fl ammable objects

ū No objects made from fl ammable material may be present or 

placed in the radiation range of the pellet fi replace (min. distance 
of 800 mm, measured from the viewing window in the combus-
tion chamber door).

ū The distance from the pellet fi replace to fl ammable materials or 

walls to be protected must be at least 50 mm at the rear and to 
the sides. 

ū The minimum distance to the side and front is 800 mm from the 

heat radiation range of the panels.

ū The distance from the exhaust pipe to fl ammable objects must be 

at least 95 mm.

Spark protection plate (Königshütte recommendation) 

ū Olsberg recommends using a sturdy and non-fl ammable spark 

protection plate with fl ammable fl oors or carpets. 

ū The spark protection plate should protrude forwards by 50 cm 

and 30 cm to the sides around the combustion chamber open-
ing here.

ū No spark protection plate is required under the pellet stove and 

under the exhaust pipe.

Humidity and living space temperatures 

ū The pellet fi replace is designed for operation in living spaces with 

normal humidity and living space temperatures of +5 °C to +25 
°C (ambient temperature during operation). Safety devices may 
come into eff ect during operation at higher temperatures. Please 
observe the appropriate information concerning heating opera-
tion here. 

Splash protection

ū The pellet fi replace does not have splash protection and may not 

be placed in wet rooms.

Installation surface 

ū The installation surface must be even, horizontal and suffi  ciently 

load-bearing. 

Combustion air supply

The pellet fi replace is exclusively operated with an open fl ue.

Please ensure that the pellet fi replace has suffi  cient combustion 
air. The cross section of the combustion air line may not be less 
than D = 80 mm.

Exhaust system and chimney design

The chimney dimensions are in accordance with DIN EN 13384 2 
and in accordance with the country-specifi c regulations.

Nominal heat output .............................................................................. 6.0 kW
Partial heat output ................................................................................... 2.1 kW
Exhaust mass fl ow .....................................................................................5.6 g/s
Exhaust temperature at the nozzle .....................................................128 °C
Minimum pump pressure at nominal heat output .........................12 Pa
Minimum pump pressure at partial heat output .............................11 Pa

If the pump pressures are too high (> 20 Pa), then you should set 
up pump pressure limitation (e.g. draft regulator in the chimney)!

Set the required pump pressure at the exhaust gas outlet to 0 Pa 
for the chimney calculation!

Multiple use of the chimney is possible with special approval 
(contact the district master chimney sweep).
The chimney must correspond to a temperature class soot fi re resist-
ance of at least T400.

Warning! Serious personal injury and environmental 
damage owing to hazardous combustion gases!

Combustion gases in the installation room which occur as a 
result of a blocked chimney are dangerous. The chimney, con-
nector and flue gas tract must be free from obstructions and 
cleaned in accordance with the manufacturer's instructions. 
Only permitted fuels may be used!

min. 4000

EN 13384-2

min. 80

min. 80

Fig. 2.7 

Exhaust gas connection

We reserve the right to make technical changes

39

| 100

Summary of Contents for Lima 2.0

Page 1: ...er Installation instructions for the specialist company Operating manual for the user Instructions de montage pour l entreprise sp cialis e Mode d emploi pour l utilisateur DE EN FR K nigsh tte Lima 2...

Page 2: ...s ajustables 10 Hauptschalter Master switch Interrupteur principal 11 Reinigungsschieber Cleaning slide Tringle de nettoyage 12 Verbrennungsluftstutzen Combustion air nozzles Manchon d arriv e d air d...

Page 3: ...and maintenance 60 Information and instructions on cleaning and care for the user Instructions on maintenance and servicing of the system for the qualified specialist company only 5 Liability for mat...

Page 4: ...e Olsberg Montage und Bedienungsanleitung ist ein Bestandteil des Olsberg Pellet Kaminofens und muss am Einsatzort sorgf ltig aufbewahrt werden Ohne diese Anleitung gilt der Pellet Kaminofen als nicht...

Page 5: ...zul ssig Halten Sie sich an vorgegebene Mindestabst nde bei der Montage und beim Gebrauch des Pellet Kaminofens Verwenden Sie niemals brennbare Fl ssigkeiten wie Benzin ben zinartige Lampen le Petrole...

Page 6: ...gsblenden vormontiert angeliefert Verpackung entfernen und Lieferumfang pr fen Sichtbare Sch den an K nigsh tte melden Abb 2 1 Lieferumfang 1 Pellet Kaminofen vormontiert mit entspr bestellter Verklei...

Page 7: ...f r den Fachbetrieb DE 2 3 Ma e 500 90 136 123 78 124 62 62 991 485 485 470 Abb 2 3 Ma e Lima Stahl Lima Naturstein 510 90 136 123 78 124 62 62 991 485 485 470 Abb 2 4 Ma e Lima Kalkstein Lima Sandste...

Page 8: ...0 mm Gewicht 112 kg Fassungsverm gen Pelletbeh lter ca 25 kg Pelletverbrauch bei max Heizleistung ca 1 4 kg h Betriebsart Dauerbrand Stromversorgung 230V 50 60Hz 1 6 A 2 5 Erforderliches Werkzeug Baus...

Page 9: ...wassergesch tzt und darf nicht in Nassr umen aufgestellt werden Aufstellboden Der Aufstellboden muss eben waagerecht und ausreichend trag f hig sein Verbrennungsluftversorgung Der Pellet Kaminofen wir...

Page 10: ...lossen in allen anderen Betriebszust nden Bereit Z nden Start ist sie ge ffnet Zum Erreichen der Endposition Zu ben tigt der Stellmotor ca 2 Minuten d h wenn die Anzeige Aus am Display erscheint darf...

Page 11: ...3 8x Abb 2 10 Untere hintere R ckwand und Blende demontieren 8 4 Abb 2 11 Verbrennungsluftstutzen abschrauben 4 Abb 2 12 Verbrennungsluftstutzen festschrauben 3 8x Abb 2 13 Untere R ckwand und mitgeli...

Page 12: ...11 Speichern 2 15 Verbrennungsluftklappe Zuluftklappe aktivieren und best tigen Wechseln Sie in das Men Komponenten Zuluftklappe ausw hlen umstellen auf mit und best tigen Verbrennungsluftklappe im M...

Page 13: ...uftklappe Zubeh r Display Flammtemperatur Raumtemperatur Wassertemperatur Ofen Hallgeber Sicherheits temperatur begrenzer Unterdruck Zuluftklappe Zubeh r Rost Zubeh r Saugzug Pelletbeh lterdeckel Puff...

Page 14: ...isplay des Touch Bedienfeldes wird automatisch aktiviert Hinweis Der m glicherweise auftretende Geruch durch das Aush rten der Schutzlackierung verschwindet wenn der Pellet Kaminofen bei guter Raumbel...

Page 15: ...K nigsh tte Lima 2 0 6 kW Pelletofen DE Technische nderungen und Irrt mer vorbehalten 15 100...

Page 16: ...inigen Sie die Brennermulde gegebenenfalls Abb 3 2 Konvektionsluft ffnungen freihalten innov ativ seit 1577 Abb 3 3 Sichtpr fung Brennermulde 3 2 Pellets einf llen ffnen Sie den Deckel des Pelltebeh l...

Page 17: ...tphase innerhalb des Bef llzeitraums lediglich der Pelletschacht gef llt und nur unzeichende 2 5 Pellets fallen in die Brennmulde Abb 3 6 Unzul ssige Bef llung Achtung Besch digung der Lackoberfl che...

Page 18: ...t Kaminofen auch in Abwesenheit in Betrieb gehen F r diesen Fall muss daf r gesorgt werden dass sich zu keiner Zeit brennbare Gegenst nde Haustiere oder hilfsbed rftige Personen im direkten Strahlungs...

Page 19: ...Beispiel Levana Leistungsstufe Bereit Party Ist in C 16 20 17 4 5 4 6 2 7 8 2 3 1 Abb 3 8 Funktionen und Informationen am Beispiel Anzeige HOME 1 EIN AUS 5 Leistungsstufen 2 Plus Minus 6 Ist Temperatu...

Page 20: ...chsten Einschaltzeit schaltet sich die Party Funktion automatisch aus und der Pellet Kaminofen arbeitet wieder wie programmiert PARTY FUNKTION AUS Durch erneutes Dr cken der Party Taste kann die Part...

Page 21: ...Konvektionsluftgebl se Frostschutz Nachtabsenkung max Leistung Standby Temperaturabfall Temperatur AUS Nachlauf Weiterf hrende Einstellungen Betriebsarten Spracheinstellungen Zeitschaltprogramme Datum...

Page 22: ...s Temperatur wird die Schalthysterese eingestellt bei der der Pellet Kaminofen im Standby Betrieb ausschaltet Die Ausschalthysterese des Pellet Kaminofens kann auf 1 C bis 3 C eingestellt werden Werks...

Page 23: ...RACHEINSTELLUNGEN Anzeige auf Deutsch Language in english Affichage en francais Abb 3 23 Touch Bedienfeld Spracheinstellungen Durch Auswahl der entsprechenden Sprache wird die Anzeige im Display angep...

Page 24: ...Anzeige INFORMATION 07 12 SW Version Wartung Betr Ext Anf 2 02 17L6 2000h 0h aus Abb 3 29 Touch Bedienfeld Anzeige von Informationen In dieser Anzeige finden sie folgende Angaben Die aktuelle Software...

Page 25: ...N gehen Sie in WLAN Einstellungen und w hlen Ihr WLAN aus Beim ersten Verkn pfen m ssen Sie dann ber das Eingabefeld das Passwort Ihres WLAN Routers eingeben Mit der Taste Aa wech seln Sie von den Buc...

Page 26: ...f dem Touchbedienfeld des Pellet Kaminofens auf die WLAN Seite Installieren Sie die App auf Ihrem Smartphone Hinweis Die WLAN Funktion des Pellet Kaminofen Lima 2 0 ist werksseitig auf eine Nutzungsda...

Page 27: ...2 APP Parameter eingeben APP Einstellungen Abb 3 44 Verbindungsaufbau abwarten 15 41 WLAN 1 Internet Verbindung herstellen WLAN Einstellungen Aktuelles WLAN Home Verbunden 2 APP Parameter eingeben APP...

Page 28: ...lossen Servicetechniker anfordern Sicherheitskette unterbrochen Eines der Sicherheitsorgane Sicherheits temperaturbegrenzer hat ausgel st Servicetechniker anfordern Flammtemperatur zu niedrig Flammtem...

Page 29: ...iten Es sind aktive Schaltzeiten hinterlegt die ak tuelle Uhrzeit ist jedoch au erhalb der aktiven Schaltzeiten In der Betriebsart Automatik ist zus tzlich keine Nachtabsenktemperatur hinterlegt Warte...

Page 30: ...s die Brennermulde herausnehmen Aschekasten und Bereich unterhalb des Aschekastenfachs reinigen nach Bedarf Der Aschekasten befindet sich hinter der Revisionst r Zum Reinigen die Verriegelung des Asch...

Page 31: ...eiche B rste Pinsel Sichtpr fung auf oberfl chliche Besch digungen 1 x pro Jahr Sichtpr fung Pr fung des Luftabgassystems L A S auf Dichtigkeit Verschlei Besch digungen 1 x pro Jahr mit Pr fger t 4 2...

Page 32: ...uteil wird in Handarbeit hergestellt Farbunterschiede bei Glasuren sowohl in Helligkeit als auchFarbt nung k nnen von Keramikbrand zu Keramikbrand in Nuancen auftre ten Diese Unterschiede k nnen deutl...

Page 33: ...K nigsh tte Lima 2 0 6 kW Pelletofen DE Technische nderungen und Irrt mer vorbehalten 33 100...

Page 34: ...ed for safe installation of the connector 1 2 Information concerning the installation instruc tions operating manual These Olsberg installation instructions and operating manual are part of the Olsber...

Page 35: ...e specified minimum distances during installation and use of the pellet fireplace Never use flammable liquids such as petrol lamp oils similar to pet rol petroleum firelighters or similar liquids to k...

Page 36: ...ial no XXX Nominal heat output NWL 6 0 kW Partial heat output TWL 2 1 kW Room heating output NWL TWL 6 0 2 1 kW Maximum operating pressure npd Fuel wood pellets Flue gas temperature exhaust socket NWL...

Page 37: ...specialist company 2 3 Dimensions 500 90 136 123 78 124 62 62 991 485 485 470 Fig 2 3 Dimensions Lima steel Lima natural stone 510 90 136 123 78 124 62 62 991 485 485 470 Fig 2 4 Dimensions Lima lime...

Page 38: ...bustion air nozzles 80 mm Weight 112 kg Pellet reservoir capacity approx 25 kg Pellet consumption at max heat output approx 1 4 kg h Operating mode Continuously burning Power supply 230 V 50 60 Hz 1 6...

Page 39: ...h protection and may not be placed in wet rooms Installation surface The installation surface must be even horizontal and sufficiently load bearing Combustion air supply The pellet fireplace is exclus...

Page 40: ...nition Start etc The actuator takes approx 2 minutes to reach the closed posi tion i e the pellet fireplace may be switched off at the master switch 2 minutes after Off appears on the display at the e...

Page 41: ...r damper on the rear of the pellet fireplace 3 8x Fig 2 10 Remove the lower back wall and panel 8 4 Fig 2 11 Unscrew the combustion air nozzles 4 Fig 2 12 Screw the combustion air nozzles tight 3 8x F...

Page 42: ...17 11 save Fig 2 15 Activate and verify the combustion air damper air flap Switch to the Components menu Select the Air flap switch to With and confirm Switch the combustion air damper on and off in t...

Page 43: ...ccessory Display Flame temperature Room temperature Watertemperature stove Hall sensor Safety temperature limiter Underpressure Supply air dampe accessory Grate accessory Induced draught Pellet tank c...

Page 44: ...the master switch to I back right of the appliance The touch control panel display is activated automatically Note the smell which may occur as a result of curing of the protective coating will disap...

Page 45: ...K nigsh tte Lima 2 0 6 kW Pellet stove GB Installation instructions for the specialist company We reserve the right to make technical changes 45 100...

Page 46: ...efore every start and clean the burner trough if necessary Fig 3 2 Keep the convection air openings clear innov ativ seit 1577 Fig 3 3 Burner trough visual inspection 3 2 Filling with pellets Open the...

Page 47: ...therwise only the pellet duct will be filled within the filling period in the start phase and only an insufficient 2 5 pellets will fall into the burner trough Fig 3 6 Prohibited filling Attention Dam...

Page 48: ...r with operat ing via the app In this case care must be taken to ensure that pets or dependants do not remain in the direct radiation range at any time and no flammable objects are placed on the pelle...

Page 49: ...vana Manual mode Ready Party Actual C 16 20 17 4 5 4 6 2 7 8 2 3 1 Fig 3 8 Functions and information using the HOME display as an example 1 ON OFF 5 Output stages 2 Plus minus 6 Actual temperature 3 T...

Page 50: ...tomatically switches off at the next switch on time and the pellet fireplace resumes working as programmed PARTY FUNCTION OFF The party function can be manually switched off by press ing the Party but...

Page 51: ...ture OFF Follow up Other settings operating modes language settings timer programs date time SETTINGS display convection frost protection night set max power n c 5 Fig 3 17 Touch control panel General...

Page 52: ...pellet fireplace switches to standby mode is set in the Off temperature menu The switch off hysteresis can be set to between 1 C and 3 C Factory setting 1 C Example Room temperature set 20 C Temperat...

Page 53: ...isplay Anzeige auf Deutsch Language in english Affichage en francais Fig 3 23 Touch control panel Language settings Selecting the appropriate language changes what is shown on the display TIMER PROGRA...

Page 54: ...ol panel Displaying information You can find the following information in this display The current software version e g 2 02 17 L6 Time to next service The pellet fireplace must be serviced at regu la...

Page 55: ...for the first time you must then enter the password for your Wi Fi router in the input field The Aa button is used to switch from letter A O to P Z as well as between upper and lower case The 12 butt...

Page 56: ...pellet fireplace To this end switch to the Wi Fi page on the touch control panel for your pellet fireplace Install the app on your smartphone Note The Lima 2 0 pellet fireplace s Wi Fi function is lim...

Page 57: ...2 Insert app credentials App settings Fig 3 44 Wait for connection set up 15 41 WiFi 1 Set internet connection WiFi settings Active WLAN Home Connection attempt 2 Insert app credentials App settings F...

Page 58: ...emperature sensor not connected Call a service technician Safety chain interrupted One of the safety devices safety temperature limit ers has triggered Call a service technician Flame temperature too...

Page 59: ...ng times Active switching times are saved and the current time is outside the active switching times In Automatic operating mode no night time reduc tion temperature is saved either Wait until the cur...

Page 60: ...red Remove the burner trough for cleaning of the combustion chamber Clean the ash pan and the area underneath the ash pan compartment As required The ash pan is located behind the inspection door For...

Page 61: ...cloth soft brush paint brush Visual inspection for surface damage 1 x per year Visual inspection Testing of the exhaust system for leaks wear damage 1 x per year With testing instrument 4 2 Maintenanc...

Page 62: ...g do not affect the functionality of the ceramics Each ceramic component is produced by hand Colour differences as well as in lightness and shade may occur in nuances between ceramic firings These dif...

Page 63: ...K nigsh tte Lima 2 0 6 kW Pellet stove GB We reserve the right to make technical changes 63 100...

Page 64: ...e de la pi ce de connexion 1 2 Remarque sur les instructions de montage et d utilisation Cette notice d installation et d utilisation Olsberg fait partie int grante du po le granul s Olsberg et doit t...

Page 65: ...ance suffisante entre le po le gra nul s y compris le conduit d vacuation d air et les rideaux tapis tissus d ameublement et autres mat riaux combustibles Il est interdit de proc der au montage sur de...

Page 66: ...mm bas 0 mm N utilisez que les carburants recommand s Lisez et suivez l instruction d utilisation EN 16501 1 Type d appareil No laboratoire d essaie No de fabrication XXX Puissance nominale PW 6 0 kW...

Page 67: ...reprise sp cialis e 2 3 Dimensions 500 90 136 123 78 124 62 62 991 485 485 470 Fig 2 3 Dimensions Lima en acier Lima en pierre naturelle 510 90 136 123 78 124 62 62 991 485 485 470 Fig 2 4 Dimensions...

Page 68: ...136 mm Manchon d arriv e d air de combustion 80 mm Poids 112 kg Capacit du r servoir granul s env 25 kg Consommation de granul s en cas de puissance de chauffage max env 1 4 kg Mode de fonctionnement...

Page 69: ...e sol doit tre niveau horizontal et suffisamment porteur Alimentation en air de combustion Le po le granul s fonctionne exclusivement avec tirage Assurez vous que le po le granul s dispose de suffisam...

Page 70: ...ion en option Le fait que la conduite d air de combustion d air soit ferm e emp che le d versement inutile d air chaud provenant du lieu d ins tallation lorsque le po le est teint Remarque En mode de...

Page 71: ...iveau du dispositif de rotation du moteur qui pourrait endommager les c bles Activer le clapet d air de combustion et v rifier qu il fonctionne normalement voir chap suivant Activer le clapet d air de...

Page 72: ...suivant Fig 2 15 Activer et confirmer le clapet d air de combustion clapet d air Passez au menu Composants S lectionner Clapet d air basculer sur avec et confirmer Activer et d sactiver le clapet d ai...

Page 73: ...heur Temp rature de flamme Temp rature ambiante Temp ratured eau po le Codeur hall Allumage Limiteur detemp rature D pression Clapet d arriv e d air accessoire Grille accessoire Tirage par aspiration...

Page 74: ...e po le granul s doit fonctionner avec des accessoires p ex thermostat Raccordez au pr alable les conduites de raccordement au connecteur Remarque M me si aucun accessoire n est utilis le connec teur...

Page 75: ...le granu l s Il est en outre confirm par les signatures de l entreprise sp cia lis e et de l utilisateur que l entreprise sp cialis e a instruit l utilisa teur de l installation notamment des risques...

Page 76: ...arrage et nettoyez la si n cessaire Fig 3 2 Grader les ouvertures d air de convection d gag es innov ativ seit 1577 Fig 3 3 Inspection visuelle de la cuvette de combustion 3 2 Remplissage des granul s...

Page 77: ...de l l ment d allumage Autrement seul le puits de granul s se remplit lors de la phase de d marrage pendant la p riode de rem plissage et seuls 2 5 granul s tombent dans la cuvette de combustion ce qu...

Page 78: ...mande via l APP le po le granul s peut galement tre mis en service en cas d absence Dans ce cas il faut s assurer qu aucun moment des animaux de compa gnie ou des personnes vuln rables ne se tiennent...

Page 79: ...7 8 2 3 1 Fig 3 8 Fonctions et informations par exemple affichage HOME 1 MARCHE ARR T 5 Niveaux de puissance 2 Plus moins 6 Temp rature r elle 3 Affichage de l heure 7 Fonction f te 4 tat de fonction...

Page 80: ...anul s s allume pour arriver en mode chauf fage Au d marrage suivant la fonction f te est d sacti v e automatiquement et le po le granul s fonctionne nouveau tel qu il a t programm Affichage tat de fo...

Page 81: ...G N RAUX Ventilateur convecteur Protection contre le gel R duction de la temp rature la nuit Puissance max Baisse de temp rature Temp rature OFF Marche vide Param tres avanc s modes de fonctionnement...

Page 82: ...R glage d usine 2 C Temp rature l arr t uniquement en mode Automatique Le menu Temp rature l arr t permet de r gler l hyst r sis d ar r t laquelle le po le granul s s arr te en mode Veille L hyst r s...

Page 83: ...e auf Deutsch Language in english Affichage en francais Fig 3 23 Panneau de commande tactile Param tres des langues Choisir la langue correspondante permet d adapter l affichage l cran Affichage CR NE...

Page 84: ...le Affichage d informations Sur cet affichage vous trouverez les informations suivantes La version actuelle du logiciel p ex 2 02 17 L6 L intervalle jusqu la prochaine maintenance Le po le granul s do...

Page 85: ...mot de passe de votre routeur Wi fi dans le champ de saisie l aide de la touche Aa vous passez des lettres A O P Z et des majuscules aux minuscules l aide de la touche 12 vous pouvez saisir les chiff...

Page 86: ...ca tion OSB IoTouch et le po le granul s Pour cela allez la page consacr e au Wi fi sur l cran tactile du po le granul s Installez l application sur votre Smartphone Remarque Par d faut la dur e d uti...

Page 87: ...ablissement de la connexion 15 41 WLAN 1 Param tres d Internet Param tres d WLAN R seau wi fi Home_ Connexe 2 Param tres de l application Application Fig 3 45 En cas de r seau Wi fi existant s lection...

Page 88: ...de s curit limiteur de temp rature de s curit s est d clench Solliciter l aide d un technicien Temp rature de flamme trop faible La temp rature des flammes a baiss de mani re inattendue Remplir le r...

Page 89: ...ors des cr neaux ho raires actifs En outre en mode automatique aucune baisse de la temp rature la nuit n est enregistr e Attendre jusqu ce que l heure actuelle soit dans les cr neaux horaires actifs e...

Page 90: ...toyer le foyer retirer la cuvette de combustion Nettoyer le bac cendres et la zone situ e sous le casse tin pour cendres Au besoin Le bac cendres se trouve sous la trappe de r vision Pour proc der au...

Page 91: ...visuel des dommages superficiels 1 x par an Contr le visuel Contr le de l tanch it de l usure et de l endommagement du syst me d chappement d air L A S 1 x par an Avec appareil de mesure 4 2 Maintena...

Page 92: ...de la nuance peuvent appara tre en nuances d une cuisson de c ramique une autre Ces diff rences peuvent appa ra tre clairement lors de la livraison de c ramiques de pi ces d tach es individuelles et n...

Page 93: ...K nigsh tte Lima 2 0 6 kW Pelletofen Pellet stove Po le pellets DE GB FR Technische nderungen vorbehalten We reserve the right to make technical changes Sous r serve de modifications techniques 93 100...

Page 94: ...e is available Note the stove ID can be found on the display under app settings or see page 57 Envoyez le certificat de mise en service page 45 46 sign la soci t Olsberg Les prestations d finies dans...

Page 95: ...e T l phone portable Bemerkungen Notes Remarques Mitarbeiterkennzeichen f r Inbetriebnahme verantwortlich Employee identifier responsible for commissioning Code de l employ responsable de la mise en s...

Page 96: ...Schadens zu erhalten bersende ich Ihnen das unterzeichnete Inbetriebnahmezertifikat Dear Sir Madam In order to receive all services pursuant to the warranty in case of damage I send you the signed com...

Page 97: ...p l i c a t e Telefon Phone D u p l i c a t e Phone T l phone D u p l i c a t e T l phone Telefon mobil D u p l i c a t e Telefon mobil Phone mobile D u p l i c a t e Phone mobile T l phone portable D...

Page 98: ...K nigsh tte Lima 2 0 6 kW Pelletofen Pellet stove Po le pellets...

Page 99: ...K nigsh tte Lima 2 0 6 kW Pelletofen Pellet stove Po le pellets...

Page 100: ...O l s b e r g Gm bH Postfach 1362 59932 Olsberg koenigshuette ofen c o m 78 4638 2061 Rev 02 07 2021...

Reviews: