12
Care and maintenance
•
Olsberg electric convector units do not require any
specific maintenance.
•
If the unit is operating in places where there is an
excess of dust, you are recommended to clean the
air inlet and outlet grilles from time to time, using a
vacuum-cleaner nozzle attachment to remove any
dust deposits.
•
DO NOT use abrasive cleaning products to remove
dirt from the outer surfaces of the unit. Use a mild
household detergent or just a soft, damp cloth.
•
Note that the unit’s connection lead is a special
part. If the lead becomes damaged, it MUST be
replaced with the appropriate original component.
Technical specifications
- Temperature-setting range........approx. 7°C to 30°C
-
Temperature-reduction phase...ca. 4.0K
-
Voltage ......................................1/N ~ 230V
-
Protection rating II ................double insulated
-
Protection class IP24 ................splash-proof
Type
Power
(watt)
Dimensions
HxWxD
1)
(mm)
Weight
(approx. kg)
Room-temperature
regulation
15/192
500
440x340x80
3.7
electronic
15/194
1000
440x420x80
4.3
electronic
15/196
1500
440x580x80
5.6
electronic
15/198
2000
440x740x80
6.7
electronic
15/199
2400
440x900x80
7.7
electronic
1)
Dimension D does not include control housing or wall-fixing bracket
Depth of wall-fixing bracket: 22mm
Note:
The identification plate is located on the back panel of the device.
When ordering spares, please be sure to indicate the type
and
serial number.