10
Wall installation
IMPORTANT:
DO NOT install the device directly be-
neath a wall-mounted power socket.
Fit the wall-fixing bracket (fig. 1) in such a way that the
convector unit lies in a
horizontal
position when in-
stalled. The attachment bracket should be fixed to a
level wall surface. Install it onto the wall using 4 x 5.5
mm max.
∅
screws, making sure that it is facing the
right way.
Note:
Use the wall-fixing bracket as a template for
marking the position of the unit and the location
of the drill holes.
Type
Dim.
L
Dim.
B
Dim.
C
15/192 340
128
106
15/194 420
208
106
15/196 580
178
201
15/198 740
320
210
15/199 900
405 247,5
Observe the international safety regulations regarding
minimum clearances when installing the unit in rooms
equipped with bath or shower.
If the unit’s connection lead is damaged, ensure that it
is replaced immediately with the appropriate original
part (available from the manufacturer or an authorized
service provider).
Locate the device on the open clips at the bottom, on
the wall-fixing bracket, and push in until the spring-
loaded catches at the top and/or sides engage in the
recesses provided in the rear panel.
To release the spring-loaded catch once it has en-
gaged, push on the upper or lateral clip with a screw-
driver or similar (see fig.1 – item Z and fig.2 – item E).
fig.1
fig.2
item
E