Wall installation

IMPORTANT:

DO NOT install the device directly be-

neath a wall-mounted power socket.

Fit the wall-fixing bracket (fig. 1) in such a way that the 

convector  unit  lies  in  a 

horizontal

  position  when  in-

stalled.  The  attachment  bracket  should  be  fixed  to  a 

level wall surface. Install it onto the wall using 4 x 5.5 

mm max.

 screws, making sure that it is facing the 

right way.

Note:

Use  the  wall-fixing  bracket  as  a  template  for 

marking the position of the unit and the location 

of the drill holes.

Type

Dim.

L

Dim.

B

Dim.

C

15/192 340

128

106

15/194 420

208

106

15/196 580

178

201

15/198 740

320

210

15/199 900

405 247,5

Observe the international safety regulations regarding 

minimum clearances when installing the unit in rooms 

equipped with bath or shower.

If the unit’s connection lead is damaged, ensure that it 

is  replaced  immediately  with  the  appropriate  original 

part (available from the manufacturer or an authorized 

service provider).

Locate the device on the open clips at the bottom, on 

the  wall-fixing  bracket,  and  push  in  until  the  spring-

loaded catches at the top and/or sides engage in the 

recesses provided in the rear panel.

To  release  the  spring-loaded  catch  once  it  has  en-

gaged, push on the upper or lateral clip with a screw-

driver or similar (see fig.1 – item Z and fig.2 – item E).

fig.1

fig.2

item

E

Summary of Contents for Confort

Page 1: ...OLSBERG Instruction Manual Confort Convector...

Page 2: ...aintenance 12 Technical specifications 12 Conditions of guarantee 13 IMPORTANT This manual MUST be handed over to the user once installation is complete Ensure also that the user receives adequate in...

Page 3: ...its components are cor rectly disposed of Disposal of old heaters Old electric and electronic devices often contain valuable materials But they may also contain harmful ingredients which were necessar...

Page 4: ...208 106 15 196 580 178 201 15 198 740 320 210 15 199 900 405 247 5 Observe the international safety regulations regarding minimum clearances when installing the unit in rooms equipped with bath or sho...

Page 5: ...ment of the room temperature to any desired level between 7 C frost protection and 30 C maximum This is carried out from the control knob which is fitted with two moulded in rear end stop pins Release...

Page 6: ...d with the appropriate original component Technical specifications Temperature setting range approx 7 C to 30 C Temperature reduction phase ca 4 0K Voltage 1 N 230V Protection rating II double insulat...

Page 7: ...appliance should be carried out by a quali fied installer The company does not accept liability for failure of any goods supplied which are not installed in accor dance with the manufacturer s instruc...

Page 8: ...20 4 78 4615 1925 03 2011 Olsberg GmbH H ttenstra e 38 59939 Olsberg T 49 2962 805 0 F 49 2962 805 180 info olsberg com olsberg com...

Reviews: