LEVANA 2.0 6 kW
LEVANA 2.0 8 kW
LEVANA AQUA 2.0
ARINA 2.0
INARA 2.0
GB
Installation instructions
for the specialist company
Activating the combustion air damper
The combustion air damper must be activated in the service level on
the touch control panel (see chap. 3.7).
●
Switch to the service level via the “Information” menu selection (for
the specialist company only)!
●
Enter the password in the service level!
Note:
The specialist dealer obtains the password for the service
menu from Olsberg customer service.
●
Switch to the “Components” menu!
●
Select the “Air flap”, switch to “With” and confirm.
●
Switch the combustion air damper on and off in the “Relay test”
menu in order to check it is functioning properly!
17:17
enter code
0
0 0 0
next
Fig. 2.25 Enter the password in the service level
convection
supply air
grate
no
no
no
17:11
save
Fig. 2.26 Activate and verify the combustion air damper (“air flap”)
.
no
no
no
relay
convection
Supply air
grate
17:11
save
Fig. 2.27 Functional test in the Relay test menu
Adjusting the pellet fireplace with the height-adjustable feet
●
Adjust the pellet fireplace in the place of installation with the
help of the height-adjustable feet before you connect the pellet
fireplace!
●
Unscrew the adjusting feet by approx. 10 mm before installation
in order to minimise sound transmission!
Fig. 2.28 Adjust the pellet fireplace with the adjusting feet
LEVANA AQUA only mounting template
●
Place the LEVANA AQUA exactly with the help of the mounting
template (optional)! Olsberg particularly recommends the use of
the mounting template with combustion air nozzles for connec-
tion from the bottom and/or water installation from the bottom.
100
80
490
100
172
120
83
123
143
143
155
90
400
155
Mindestabstand bei zu
schützenden Wänden
(hinten und seitlich
100mm)
Verbrennungs-
luftanschluß
Rohrdurchmesser
D=80mm
Heizungs-
vorlauf 1/2"
Heizungs-
rücklauf 1/2"
43/1491.9001
(LEVANA AQUA)
Stellfuß
Fig. 2.29 Position the pellet fireplace with the mounting template
(optional)
66
We reserve the right to make technical changes
| 154