1.Location in the following places may cause malfunction of the machine. (If unavoidable,
please consult your local dealer)
a. A place where there is flammable gas leakage.
b. There is salty air surrounding(near the coast).
c. There is caustic gas(the sulfide, for example) existing in the air (near a hot spring).
d. A place where can not bear the weight of the machine.
e. In kitchen where it is full of oil gas
f. There is strong electromagnetic wave existing.
g. There is acid or alkaline liquid evaporating.
h. A place where air circulation is not enough.
I.The appliance shall not be installed in the laundry
2. Electrical Insulation must be done on the air conditioner and the building complying to
National Regulations.
CAUTIONS
INSTALLATION LOCATIONS
HEIGHT BETWEEN CEILING AND FLOOR
INSTALLATION SPACE
B
C
Wall
material
Up(B)
Sides(C)
Above 5cm
Above 5cm
Above 5cm
Above 100cm
Above 100cm
Flammable
material
Fire-proof
structure
Fire-proof material
or other nonflammable
materials other than
metal
A
Ceiling
Above 250cm
Above
100cm
Above
100cm
Obstacle
INDOOR UNIT INSTALLATION
The installation height between ceiling and floor must be 2.7m~3.2m.
5
A>330mm