Operation instructions
6
SMART mode(
)
invalid for
some models
Heat pump models
T+3
℃
or below
(3°F)
Heat pump models
Cooling only models
Indoor temperature
Target temperature
Below T-3
℃
(3°F)
T
T
T
O
(3°F)
ver T+3
℃
O
(3°F)
ver T+3
℃
T-3
℃
T+3
℃
(3°F)
≤
≤
(3°F)
T
indoor
Operation mode
HEATING
FAN ONLY
COOLING
Indoor temperature
Target temperature
T
T
Operation mode
FAN ONLY
COOLING
How to set SMART mode?
Press the
button.
Result :
Enter
SMART
mode(fuzzy logic operation)
directly regardless of the unit is on or off.
Temperature and fan speed are automatically
set based on the actual room temperature.
PRESS
Note: Temperature, airflow and direction are controlled automatically in SMART mode. However, For the on/off,
you can choose from -2 to 2, for the inverter you can choose from -7 to 7. if you still feel uncomfortable.
ECONOMY button is ineffective in SMART mode.
Press MODE button to cancel SMART mode.
For the split-type models, such as wall-mounted air conditioners and some floor-standing air conditioners,
their operation mode and set temperature should be determined based on the indoor temperature.
For commercial air conditioner products, such as cassette type air conditioners, duct type air conditioners,
ceiling & floor air conditioners and some floor-standing air conditioners, their operation mode should be
determined based on the difference between the indoor temperature and set temperature.
Indoor temperature
Target temperature
21
70
℃
or below
(
°F)
22
℃
(72°F)
26
℃
(79°F)
Over 26
℃
(79°F)
21
(
70
°F-73°F)
℃
-23
℃
23
(
73
°F-79°F)
℃
-26
℃
Operation mode
HEATING
FAN ONLY
DRY
Room temperature
decrease 2
(3°F)
℃
after
operate for 3 minutes
COOLING
Cooling only models
Indoor temperature
Target temperature
23
℃
or below
(73°F)
26
℃
(79°F)
Over 26
℃
(79°F)
23
(
73
°F-79°F)
℃
-26
℃
Operation mode
FAN ONLY
DRY
Room temperature
decrease 2
(3°F)
℃
after
operate for 3 minutes
COOLING
Some models do not have the SMART mode. The SMART button is not available.
SMART button is ineffective in SUPER mode.
Summary of Contents for OSH-07FRH2
Page 15: ...UA EDGE Inverter NEW OSH 07FRH2 OSH 09FRH2 OSH 12FRH2 OSH 18FRH2 OSH 24FRH2...
Page 16: ...SUPER QUET SMART ECO DIMMER TIMER OFF LOCK SLEEP I FEEL 8 C TIMER ON CLEAN...
Page 18: ...1 2 3 2 LR03 AAA 1 5 7...
Page 20: ......
Page 28: ...OLMO...
Page 29: ...RU EDGE Inverter NEW OSH 07FRH2 OSH 09FRH2 OSH 12FRH2 OSH 18FRH2 OSH 24FRH2...
Page 30: ...SUPER QUET SMART ECO DIMMER TIMER OFF LOCK SLEEP I FEEL 8 C TIMER ON CLEAN...
Page 32: ...1 2 3 2 LR03 AAA 1 5 7...
Page 34: ...SWING...
Page 42: ...OLMO...
Page 43: ......
Page 44: ......