2H0/2HZ
1-3-29
U067
Adjusting the scanner center line
Description
Adjusts the scanner center line of the original scanning.
Purpose
Make the adjustment if there is a regular error between the center lines of the copy image and original.
Adjustment
1. Press the start key.
2. Select the item to be adjusted.
3. Press the system menu key.
4. Place an original and press the start key to make a test copy.
5. Press the system menu key.
6. Change the setting value using the +/- or numeric keys.
For copy example 1, decrease the value. For copy example 2, increase the value.
Figure 1-3-12
7. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display
Description
Setting
range
Initial
setting
Change in
value per step
ADJUST DATA 1
Scanner center line
-70 to 70
0
0.085 mm
ADJUST DATA 2
Scanner center line (rotate copying)
-25 to 25
0
0.085 mm
Original
Copy
example 1
Copy
example 2
Scanner center line
U067
U403
U072
U404
Y108620-5 Service Manual
Summary of Contents for d-Copia 2500MF
Page 1: ...d Copia 2500MF d Copia 3000MF Digital Copier SERVICE MANUAL Code Y108620 5...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 14: ...2H0 2HZ This page is intentionally left blank...
Page 20: ...2H0 2HZ 1 1 6 This page is intentionally left blank Service Manual Y108620 5...
Page 258: ...2H0 2HZ 2 1 20 This page is intentionally left blank Service Manual Y108620 5...
Page 296: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2007 1ST EDITION 296 Y108620 5...