64
MISFEED REMOVAL
When the misfeed (
) indicator blinks or
blinks in the display, the unit will
stop because of a misfeed. If a misfeed occurs when using the SPF, a number may
appear in the display after a minus sign. This indicates the number of the originals
that must be returned to the original feeder tray after a misfeed. Return the required
number of originals. Then this number will disappear when copying is resumed or the
clear (
) key is pressed. When the SPF misfeeds an original sheet, the unit will
stop and the SPF misfeed (
) indicator will blink, while the misfeed (
) indicator
will remain off. For a misfeed of originals in the SPF, see "D: Misfeed in the SPF (d-
Copia 201D)" (p.68).
1
Open the multi-bypass tray,
and then open the side
cover.
2
Check the misfeed location. Remove the misfed paper
following the instructions for each location in the illustration
below. If the misfeed (
) indicator blinks, proceed to "A:
Misfeed in the paper feed area" (p.65).
If paper is misfed here, proceed to "
A:
Misfeed in the paper feed area
". (p.65)
If paper is misfed here, proceed to "
B:
Misfeed in the fusing area
". (p.66)
If the misfed paper is seen from
this side, proceed to "
C: Misfeed
in the transport area
". (p.67)