MODEL 619-16, 20, 24, & 24R DOUGH DIVIDERS
TROUBLE SHOOTING GUIDE
The
“End of Stroke Light” does not come on.
Possible Causes
·
There may be a disconnected wire.
·
The bulb may have burnt out.
·
The limit switch is not adjusted properly.
·
The limit switch is not operating and needs replacement.
The motor
“Hums” but will not start.
Possible Causes
·
The motor is a dual voltage motor and may be wired for high voltage, but, an
attempt is being made to run it on low voltage.
·
The electric supply to the motor is single phase instead of three phase.
·
One of the leads of the three phase system has opened.
The motor runs but
“Stalls” at either end of the cylinders travel.
Possible Causes
·
The incorrect overload relay was installed or the setting of that overload
relay is incorrect.
·
The setting of the hydraulic relief valve is to high.
The motor runs
“Slowly” but stalls easily before completion of its stroke.
Possible Causes
·
The motor is wired for high voltage but is connected to a low voltage supply.
The motor has
“Stalled” and can not be restarted.
Rev. 1-31-96
Summary of Contents for MODEL 619-16
Page 23: ...REV 4 23 97 0619S20008 MODEL 619 16 20 24 24R DOUGH DIVIDERSMAIN FRAME ASSEMBLY DRAWING...
Page 24: ...0619S20145 COVERS ASSEMBLY DRAWING FRAME ASSEMBLY...
Page 25: ...0619S20010 MODEL 619 16 20 24 24R DOUGH DIVIDERS HYDRAULIC ASSEMBLY DRAWING Rev 12 21 04...
Page 26: ...REV 1 23 02 0619S20011 MODEL 619 16 20 24 24R DOUGH DIVIDERS LID ASSEMBLY DRAWING...
Page 27: ...REV 5 30 00 0619S20043 MODEL 619 16 20 24 24R DOUGH DIVIDERS 16 PART PUSHER ASSEMBLY DRAWING...
Page 28: ...REV 5 30 00 0619S20012 MODEL 619 16 20 24 24R DOUGH DIVIDERS 20 PART PUSHER ASSEMBLY DRAWING...
Page 31: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 33: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 35: ...GEN020319 THIS PAGE WAS INTENTIONALLY LEFT BLANK...