Minimum cord size (AWG) required based on amperage draw and length of the cord:
Amps
Power Cord Length
25 feet
50 feet
75 feet
100 feet
> 100 feet
< 5
16
14
14
14
NR
5 to 8
14
14
14
12
8 to 12
14
14
12
10
12 to 15
12
12
10
10
15 to 20
10
10
10
NR
21 to 30
10
NR
NR
NR
*NR: Not Recommended
WARNING
Use properly sized wires that meet or exceed the power requirement of your
machine. Using undersized wires may cause overheating and increase the risk of fire
and machine damage.
WARNING
Improper copper-aluminum wire connection is a fire hazard. If the power circuit
available uses aluminum wires, use certified CU/AL wire connectors.
Summary of Contents for 4430
Page 2: ......
Page 10: ...10 Page Oliver Machinery 4430 Planer Identification...
Page 11: ...4430 Planer OLIVERMACHINERY NET 11 Page...
Page 12: ...12 Page Oliver Machinery 4430 Planer...
Page 38: ...38 Page Oliver Machinery 4430 Planer Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6...
Page 50: ...50 Page Oliver Machinery 4430 Planer Wiring Diagram...
Page 51: ...4430 Planer OLIVERMACHINERY NET 51 Page Parts List Table Assembly...
Page 52: ...52 Page Oliver Machinery 4430 Planer Cabinet Assembly...
Page 53: ...4430 Planer OLIVERMACHINERY NET 53 Page Motor Mount Assembly...
Page 54: ...54 Page Oliver Machinery 4430 Planer Headstock Assembly...
Page 55: ...4430 Planer OLIVERMACHINERY NET 55 Page Gearbox Assembly Cover and Dust Hood Assembly...
Page 62: ...62 Page Oliver Machinery 4430 Planer Maintenance Record Date Task Operator...
Page 63: ...4430 Planer OLIVERMACHINERY NET 63 Page Notes...