58
ENGLISH
PARAMETER NAME
RANGE
DEFAULT
COMMENTS
Periodic DHW pump
activation
ON, OFF
ON
If ON and the DHW pump is OFF, it will be switched ON
with interval and duration defined by the following two
parameters
DHW pump activation
interval
0 -100 hours
72
DHW pump activation
duration
0 – 600 seconds
30 sec
DHW pump maintenance
delay
0-999 days
0 days
Device modbus address
0 - 255
1
RS485 MODBus comm. port address to be used by any
remote control device (PCs, others)
3.1.14
FIRMWARE (fig. 45)
Touching the Firmware
on the “Menu” page calls up the firmware updating window.
This window, to be used by the technical service, is used to update the display software.
Before selecting this page, the USB memory stick must be plugged into the relative port on the display card (fig. 6a ref. A).
Any operations on the electric panel must only be performed once the power has been disconnected using the master switch.
Press the software update
icon to proceed with updating.
On completion the control will switch itself off and then restart again.
Before removing the memory stick, touch the removal
icon.
3.1.15
DISPLAY (fig. 46)
Touching the Display
icon on the “Menu” page calls up the window for displaying/setting the screen.
This window is used to select the language used for the various windows, to set the screen saver delay time and to adjust the
brightness of the screen.
3.1.16
SPECIAL FUNCTIONS (fig. 47)
The special functions
icon on the “Menu” page calls up the following sub-windows:
Touching the Anti-legionella
icon calls up the window for displaying/setting programmed disinfection of the domestic hot water
tank. Changing the function parameters is allowed once the Service or installer’s password has been entered.
The disinfection parameters are:
• Function mode. The function can be performed using the heat pump and the heaters in the internal unit or using the heaters
located in the domestic hot water tank.
• Cycle activation interval
• Disinfection cycle start time
• Water temperature during the disinfection cycle
• Duration of the disinfection cycle
You are reminded that with the heat pump circuit built into the internal unit, the Sherpa Aquadue can produce hot water up to
75°C without the need for electric heaters.
If during the anti-legionella cycle the disinfection temperature is reached but it is not maintained for the entire duration of the cycle
requested, the function will be repeated after 24 hours; if the second attempt also fails, the system triggers alarm A8 and will not
produce any more domestic hot water.
Setting the activation interval to 0 days will deactivate the anti-legionella function.
Running the Anti-legionella cycle is signalled on the display by the disinfection
icon and the system exits the function after
a maximum of 7 hours if for any reason the required temperature has not been reached inside the tank.
To prevent scalding if tapping off hot water during the disinfection cycle, it is advisable to install anti-scalding safety devices on
each utility or at the domestic water tank outlet.
3.1.17
PUMPS (fig. 49)
The Pumps icon
, calls up the window for activating/deactivating the circulation pumps and the three-way valve once the
Service or installer’s password has been entered.
These functions can only be activated with the unit in standby mode.
3.1.18
RATING (fig. 50)
The Rating icon
, (only for use by Service technicians), calls up the external unit PID control window once the password has
been entered.
3.1.19
DIAGNOSTICS (fig. 51)
The Diagnostics icon
calls up a window with the following information once the Service Password has been entered:
3
Summary of Contents for OS-CEBCH36EI
Page 1: ......
Page 2: ...2 1 3 2 U H A S G I F C N E T D R N O M U B L V Z ...
Page 3: ...3 5 4 A B C ...
Page 4: ...4 7 D D D C A M H G I F E B D L 6 A B 6a A A ...
Page 6: ...6 16 15 A B E F E G H C D 14 13 C D A B A H B C D E F E G 11 12 B A ...
Page 10: ...10 B C A D C E F C G 25 27 26 29 28 31 30 ...
Page 11: ...11 33 32 35 34 36 37 A C D B 2 3 1 E 4 5 6 7 8 9 ...
Page 12: ...12 39 38 41 40 43 42 45 44 ...
Page 13: ...13 47 46 49 48 51 50 52 ...
Page 14: ...14 ...
Page 38: ...3 ...
Page 62: ...3 ...
Page 86: ...3 ...
Page 87: ...3 ...
Page 88: ...www olimpiasplendid it info olimpiasplendid it 277415B 1 ...