NEXYA S5 E
ENGLISH
EN - 5
29. Do not drink the water drained from the product.
It is not sanitary could cause serious health issues.
30. When there are gas leaks from other units, ventilate the room well before activating the
air conditioner.
31. Do not disassemble or modify unit.
32. Ventilate the room well when used together with a stove, etc.
33. Do not use for special purposes.
34. The persons that work or intervene on a cooling circuit, must be in possession of suitable
certification, issued by an accredited assessment body. This must attest skill in safely
handling refrigerants in compliance with assessment specification acknowledged by
sector associations.
35. Do not emit R32 gas into the atmosphere; R32 is a fluorinated greenhouse gas with a
Global Warming Potential (GWP) = 675.
36. The appliances described in this manual are in compliance with the applicable European
Directives and successive amendments.
37. The appliance contains A2L inflammable gas. For the correct mode of installation,
please consult this manual.
0.2 - NOTES REGARDING FLUORINATED GASES
• This climate control appliance contains fluorinated gas. For specific information
regarding the type and quantity of gas, refer to the data plate affixed to the unit.
• The installation, assistance, maintenance and repair of the appliance, must be
performed by a qualified certified technician.
• Product removal and re-cycling operations must be performed by a qualified certified
technician.
• If the system has a leak-detection device installed, the checks for leaks must be
performed at least every 12 months.
• When the unit is checked for leaks, keeping a record of all inspections is highly
recommended.
• Before starting to operate on the appliance, it is necessary to check the zone surrounding
the equipment to make sure there are no dangers of fire nor risks of combustion.
To repair the refrigerating system, it is necessary to take the following precautions
before starting the intervention on the system.
1. The zone MUST be checked with a specific refrigerating liquids detector before and
during work, so that the technician is aware of potentially flammable atmospheres.
Make sure the detection device of the leaks is suitable for use with flammable
refrigerants, then that it does not produce sparks and that is adequately sealed or
intrinsically safe.
2. The leakage electronic detectors may need calibration.
If necessary, calibrate them in a zone free of refrigerant.
3. Make sure the detector is not a potential source of combustion and that it is suitable
for the refrigerant used. The device for detection must be set at a percentage of
the refrigerant LFL and must be calibrated for the used refrigerant; the appropriate
percentage of gas (maximum 25 %) must be confirmed.
3a. The leakage detection fluids are suitable for most of the refrigerants. The detergents
containing chlorine MUST be avoided.
Danger of corrosion of the copper pipes.
4. If the presence of a leak is suspected, all open flames must be removed.
5. All sources of combustion (even a lit cigarette) should be kept away from the place
in which all operations during which the flammable refrigerant may be released in
the surrounding space must be carried out.
Summary of Contents for NEXYA S5 E CASSETTE
Page 2: ......
Page 7: ...3 5 4 7 8 2 4 7 3 5 6 9 7 M L N 7 C B A min 120mm min 150mm min 120mm min 2000mm max 3000mm 1...
Page 8: ...min 1500mm 12 11 13 22 23 24 23 24 22 14a 26 27 28 29 30 28 14b 10 D E C B A F...
Page 9: ...15 16 8m A B E G C D F F1 17 18 22 21 4 2 1 5 10 6 4 11 3 8 7 9 19 20...
Page 10: ...23 24 click 25 26 29 30 a b 27 28...
Page 335: ...NEXYA S5 E EL 3 0 0 1 1 OL PIA SPLENDID 2 3 4 5 6 7...
Page 336: ...EL 4 8 9 10 11 12 13 OLIMPIA SPLENDID 14 15 16 17 18 19 20 21 22 23 24 25 26 27...
Page 338: ...EL 6 6 7 8 9 9a OFN 9b OFN 10 OFN 10a 11 12 13 14 OFN 14b 14b 14c...
Page 339: ...NEXYA S5 E EL 7 15 16 17 18 19 0 5 20 21 22 23 24 DPI 25 26 27 0 3 X OLIMPIA SPLENDID 0 4...
Page 340: ...EL 8 0 5 T20A 250 VAC 24000 Btu h T30A 250 VAC 24000 Btu h R32 s 0 6 a b c d e CO2 f...
Page 341: ...NEXYA S5 E EL 9 g h i l...
Page 344: ...EL 12 1 5 a b c 3 d e OLIMPIA SPLENDID 3 2 2 1 X m2 7 4 X m2 7 4 OLIMPIA SPLENDID...
Page 363: ...NEXYA S5 E EL 31 6 30 a b ON OFF MODE COOL HEAT 5 c 17 C COOL 2 2 6 1...
Page 374: ...EL 42 COOL 8 8 SLEEP ECONOMY 8 9 COOL FAN HEAT 9 0 OFF 9 1 a b c d...
Page 375: ...NEXYA S5 E EL 43 a b c 9 2 COOL HEAT TIMER ON 9 3 9 3 1 9 3 2 26 27 28 29 30 a 26 b 28a 28b...
Page 376: ...EL 44 c d e 29 10 f g h 30 i 10 10 1 10 2 3...
Page 377: ...NEXYA S5 E EL 45 7 C SILENCE SILENCE 10 3 1 a 3 b 4 10 2 COOL 3...
Page 379: ......
Page 380: ...264707C...