DOLCECLIMA
EN - 25
ENGLISH
4.2.b Error codes
During the appliance functioning, a few anomalies which stop its functioning could appear.
In these cases, some error codes appear on the control panel.
• P1
Lower tray full.
•
Empty it by operating as described in paragraph 4.2.a
-------------------------------------------------------------------
• F1
Filters cleaning.
•
Message
F1
appears every 250 hours of operation of the fan motor.
Proceed with the filters cleaning (paragraphs 4.1.b - 4.1.c - 4.1.d) and reset the hours counting by
keeping key
“
ON/OFF
” on the appliance control panel pressed for 5 seconds.
-------------------------------------------------------------------
• E1
Environment temperature sensor error.
• E2
Evaporator temperature sensor error.
• E3
Condenser temperature sensor error
• E4
Display panel communication error.
In these cases:
a.
electrically disconnect the appliance
b.
wait a few minutes
c.
connect the plug to the power socket
d.
restart the appliance.
If the inconvenience persists and the error code doesn’t turn off, electrically disconnect the
appliance and refer to an Assistance Centre.
5 - TECHNICAL DATA
For the technical data, please consult the data plate applied to the product (Fig.2).
• Dimensions (W x H x D)
460 x 767 x 395 mm
• Weight (without packing)
29 Kg
• Maximum operating temperature
in cooling mode
DB 35°C - WB 24°C * / DB 43°C - WB 32°C **
DB 27°C - WB 19°C * / DB 27°C - WB 19°C **
• Minimum operating temperature
in cooling mode
16°C * / 16°C **
DB 7°C * / DB 7°C **
* Internal ambient temp.
** Outside ambient temp.