24
EN
WARNING:
Water that has flown
through backflow preventers is
considered to be non- potable.
IMPORTANT:
Only clean or filtered
water should be used for intake.
The delivery of the water intake tap
should be equal to the double of
the maximum pump range.
Place the cleaner as close to the water
supply system as possible.
Failure to comply with the above
conditions causes serious mechanical
damage to the pump and the loss of
warranty cover.
Water supply from the potable water
mains
· Connect a supply hose (not includ-
ed) to the water inlet of the unit
and to the water supply.
· Open the tap.
Water supply from an open container
· Unscrew the coupling part for the
water inlet.
· Screw the suction hose with filter
(not included) onto the water con-
nection of the unit.
· Hang the filter in the container.
· Vent the unit before operation.
· Unscrew the high-pressure line at
the high pressure outlet of the unit.
· Switch on the unit and let it run
until water free of bubbles emerges
at the high-pressure outlet.
· Switch off the unit and screw on
the highpressure hose again.
>
ELECTRICITY SUPPLY
- The electrical connection of the
appliance must be carried out by a
QUALIFIED
ELECTRICIST and conform to the
norm IEC 60364-1.
WARNING:
Before connecting
the appliance, make sure that the
nameplate data are the same as
those of the electrical mains and
that the socket is protected by a
differential security breaker with
tripping sensitivity below
0.03 A - 30 ms.
- If the appliance’s plug is not com-
patible with the socket, have the
socket replaced with another of
suitable type by professionally
qualified staff.
- Never use the appliance in ambi-
ent temperatures below 0° C if it is
equipped with a PVC
(H VV-F) cable.
WARNING:
Inadequate exten-
sion cords can be dangerous. If
an extension cord is used, it must
be suitable for outdoor use con-
nections must be dry, away from
the ground and a cable reel must
be used so that the socket is at a
distance of at least 60 mm from the
ground.
<16 A
<25 A
<20 m
ø 1,5 mm
2
14 AWG
ø 2,5 mm
2
12 AWG
20 m - 50 m ø 2,5 mm
2
12 AWG
ø 4,0 mm
2
10 AWG
IMPORTANT:
The Total Stop
device, which stops the machine
during the bypass phase. To start
the water cleaner, it is therefore
necessary to set the switch on
position (I)“ON”; after that press the
pistol trigger. The Total Stop System
will start the machine and will stop
Summary of Contents for PW 115C
Page 2: ......
Page 4: ......
Page 6: ...6 1 4 2 5 3 5x 4x...
Page 13: ...13 1 Optional 2A 3A 2B 3B E...
Page 52: ...52 EL...
Page 54: ...54 EL 13mm IEC 60364 1 0 03 A 30 ms 0 C PVC H VV F 60 mm...
Page 56: ...56 EL 10 2012 19 EU 2012 19 EU...
Page 62: ...62 A RU UK...
Page 64: ...64 RU 13 QUALIFIED ELECTRICIST IEC 60364 1 0 03 0 0 H VV F 60...
Page 66: ...66 RU 10 2012 19 EU 2012 19 EU...
Page 112: ...112...
Page 114: ...114 13 1 2 IEC 60364 1 0 03 A 30 ms 0 C PVC H VV F...
Page 116: ...116 10 2012 19 2012 19...
Page 124: ...124 24 12 1 2 3 4 u942 5 6 7 8 9...
Page 126: ...126 24 12 1 2 3 4 5 6 7 8 9...
Page 136: ...136 24 12 1 2 3 Bulgarian 4 a b c d e 5 6 7 8 9...
Page 137: ...NOTE...
Page 138: ......
Page 139: ......