![Oldham BM25 User Manual Download Page 60](http://html.mh-extra.com/html/oldham/bm25/bm25_user-manual_730578060.webp)
60
BM 25/25W
Instruction Manual
Sensor fault:
■
Visual and Audible alarm (continuous)
■
Clear message on the display
Battery fault:
■
Visual and Audible alarm (continuous)
■
Clear message on the display
Inputs and outputs
Inputs/Outputs
■
RS232 infrared link
■
Alarm relay output
■
Fault relay output
■
Dry Logic input
■
Optional Wireless Communication (2.4GHz - 100 mW)
Additional software
Additional software:
Maintenance software
COM 2100
Power supply
Power Supply:
NiMH rechargeable battery pack
Battery life in hours
(excluding alarms and as a
function of the number of
sensors):
Configuration
Without radio
module (hours)
With radio
module (hours)
1 catalytic and 2
infrared
40
35
1 catalytic and 1
infrared
70
50
1 catalytic and
several Tox
100
65
Only Tox sensors
170
135
Charging Time:
4.5 hours
Weight and dimensions
Weight:
6.85 kg
Dimensions:
470 x 180 x 190 mm (H x W x D)
Certification
Ingress Protection:
IP 66
Certifications:
CE, ATEX, IECEx, FCC
Summary of Contents for BM25
Page 1: ...BM 25 25W Area Gas Monitor Part Number NPB25EN Version L 2 User Manual ...
Page 8: ...8 BM 25 25W Instruction Manual ...
Page 10: ...10 BM 25 25W Instruction Manual Product Overview Figure 2 Product Overview ...
Page 18: ...18 BM 25 25W Instruction Manual ...
Page 34: ...34 BM 25 25W Instruction Manual ...
Page 70: ...70 BM 25 25W Instruction Manual ...
Page 76: ...76 BM 25 25W Instruction Manual ...
Page 78: ...78 BM 25 25W Instruction Manual ...