![Okura Robot Palletizer A Series Operation Manual Download Page 9](http://html1.mh-extra.com/html/okura/robot-palletizer-a-series/robot-palletizer-a-series_operation-manual_3664568009.webp)
3-1
3. Setup
3.1. Configuration ABC
Refer to Document of AnyBus Communicator about an setup.
Screen 1
1.
ABC and PC are connected by Configuration Cable
2.
DC24V supplied to ABC
3.
Execution of ABC Config Tool displays [Select Configuration] (Screen 1).
4.
A [Cancel] button is clicked and [Select Configuration] is closed
5.
COM 1-3 is chosen by /Tools/Port
6.
Configuration File is opened by Menu/File/Open
7.
[Connect] button of Toolbar is clicked
8.
The [Download to ABC] button of Toolbar is clicked
9.
Download is performed
Configuration File means the following files.
Profibus
AbcRc101ProfiDp.cfg
Ethernet/IP
AbcRc101EtherNetIP.cfg