4742-E P-39
SECTION 1 INVERTER UNIT (MIV UNIT)
6-3.
SWM Monitor Unit
6-3-1. Connection
Eeospcsa1032
•
Be sure to turn off the control power of the MIV unit before connecting the SWM unit.
(Disconnect the 24 VDC connector or turn off the circuit breaker of the machine.)
•
Connect the SWM monitor unit directly to the MIV unit as shown in the figure below.
(No indication is given to the connector with which the SWM unit is connected, refer to the fig-
ure below.)
(1) SWM unit connection drawing for MIV*-1
EIOSPCSA1043R01
(2) SWM unit connection drawing for MIV*-3
EIOSPCSA1042R01
UNIT TYPE
MIV0404-1-B1
DCA DCB
SR
ST
C1
C2
232
SWM unit connection
connector
SWM unit
MIV unit
MIV unit
E1M
E2M
BRA BRB
ON
12345
ON
12345
UNIT TYPE
MIV06-3-V1
ON
12345
DCA DCB
AC
FU
XT2(U V W )
SR
ST
C1
C2
232
EPG
RES
CHG
SWM unit connection
connector
SWM unit
MIV unit
MIV unit
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com