background image

DISPLAY SETUP

---------------------------------------

DOME LABEL

OFF

PRESET LABEL

OFF

ZOOM LABEL

OFF

ZONE LABEL

OFF

DIRECTION LABEL

OFF

TEMPERATURE LABEL

OFF

TIME LABEL

OFF

DATE LABEL

OFF

BACK

[DOME LABEL] :
[PRESET LABEL]:
[ZOOM LABEL]:
[ZONE LABEL]:
[DIRECTION LABEL]:
[TEMPERATURE LABEL]:

[TIME LABEL]:
[DATE LABEL]:

show label name

show preset label or scan label

show zoom ratio

show zone Label

show the coordinate position

show the current dome

temperature

show the current time

show the current date

Zone
label

Direction
label

Preset
label

Time

Date

Zoom ratio indicator

Auto flip:

Proportional Pan:

Park time:

Park Action:

Power Up Action:

FAN Enable:

The dome swing the PAN to 180°, when the limit of 90°TILT reach

Inversly controlling

Set the IDLE timer in minutes, and activates the action defined in “PARK ACTION”.

Define the action when “Park time” activate. Selcetable: Preset 1-80, Scan 1-4, Pattern1-4,

Tour 1-4

Start “Park Action” when power up.

Define the temperature limit for the internal cooling fan.

MOTION

--------------------------------

AUTOFLIP

ON

PROPORTION PAN

ON

PARK TIME

005

PARK ACTION

BACK
EXIT

SCAN

POWER UP ACTION

AUTO

FAN ENABLE

040

ADVANCE SETTING ->

The “CLEAR” function resets the settings to factory default.

Delete all zones setting

Delete all preset positions

Delete all pattern setting

Delete all tours setting

Delete all privacy masking setting

Reset all setting and return to factory settings

Restart the dome

Note: after using the option “Factory default”, all system setting and stored information such as preset, tour or pattern will be
erased permanently. Please make sure before proceeding.

CLEAR ALL ZONES:
CLEAR ALL PRESET:
CLEAR ALL PATTERNS:
CLEAR ALL TOURS:
CLEAR ALL WINDOWS:
FACTORY DEFAULT:
RESTART:

CLEAR

-------------------------------

CLEAR ALL ZONES
CLEAR ALL PRESET
CLEAR ALL PATTERNS
CLEAR ALL TOURS
CLEAR ALL WINDOWS
FACTORY DEFAULTS
RESTART
BACK
EXIT

The password function can prevent unauthorized access to the OSD and change the setting. It consists a 6 digit number
from 0-9 and can be disable.

Enter the old password

: Enter the new password with 6 digit number

Enter the new passwor again

ENABLE PASSWORD: Activate the login function to the OSD
Default password: 000000
Supervisor password: 892226

OLD PASSWORD:
NEW PASSWORD
CONF PASSWORD:

PASSWORD SETTING

---------------------------------

OLD PASSWORD ******
NEW PASSWORD ******
CONF PASSWORD ******
ENABLE PASSWORD OFF
BACK
EXIT

The system is equipped with a RTC (Real-Time Clock) and can be used to display the date/ time information on the
screen, or schedule enabled operation. In order to use these functions correctly, you need to setup at first.

Change the time setting

Change the date setting

Use [LEFT], [RIGHT] to move the cursor and use [UP], [DOWN] to adjust the value. When finished, press [IRIS OPEN] to
save the setting.

TIME:

DATE:

CLOCK SETTING

--------------------------------

TIME:

HH:MM:SS

DATE:

YY/MM/DD

BACK
EXIT

System Setting

Display Setup

OSD SETUP

English

System Setting

Motion

System Setting

Motion

Advance Setting

ADVANCE SETTING

--------------------------------

EIS ANABLED

N/A

PRESET FREEZE

N/AI

IR HEADLIGHT
MANUAL
HEAD-DOWN

OFF

DEFOGGER

15

WIPER
BACK
EXIT

EIS ANABLED
PRESET FREEZE:
IR HEADLIGHT:
HEAD-DOWN:
DEFOGGER:
WIPER:

: Electronic Image Stablizer. Depends on the camera model, it might not be available.

Freezes the preset image

Performance of the IR-Headlight, selectable with Low, Medium, High or Manual.

When installing the PTZ reversed, turn on this option.

Defogger function in the camera bay.

Starts the Wiper

System Setting

Clear

System Setting

Password Setting

System Setting

Clock Setting

5

Summary of Contents for SEIMW36T-V53DN

Page 1: ...36x Wide Dynamic ICR IR PTZ Camera OPERATION MANUAL SEIMW36T V53DN OKINA...

Page 2: ...nent damage and avoids the warranty For indoor application with extrem wet condition or area contains water or high humidity use the outdoor model instead When the indoor PTZ get wet turn off the powe...

Page 3: ...Menu System Setting Edit dome label Initial Info Display Setup Motion Motion Advanced Setting Clear Password Setting Clock Setting Camera Setting IR CUT Filter Function Setting Presets Scan Pattern T...

Page 4: ...ID 4 Termination ON Use 4 Screws to fix not included Wall Mount Bracket optional accessory Reverse Mount Use 4 Screws to fix not included Change SETTING in OSD Mounting Use 4 Screws to fix not includ...

Page 5: ...cessary to consider the environmental in fluences when planning the installation If the transmission requires a larger distance you may use video balun or fiber transmitter to extend the distance Cont...

Page 6: ...ontrol Make sure that your controller device supports these functions Zoom in PAN Zoom out TILT The PAN and TILT function are mostly performed from the Joystick on the keyboard Please refer to the use...

Page 7: ...ect the desired character and RIGHT for next input Available characters appear in following order Use LEFT to move to previous character when edit In case you need to delete a character use the SPACE...

Page 8: ...LEARALLTOURS CLEARALLWINDOWS FACTORYDEFAULT RESTART CLEAR CLEAR ALL ZONES CLEAR ALL PRESET CLEAR ALL PATTERNS CLEAR ALL TOURS CLEAR ALL WINDOWS FACTORY DEFAULTS RESTART BACK EXIT The password function...

Page 9: ...erent environment In shutter mode the camea changes the shutter speed to regulate light Regulate the Iris openning to control the exposure Regulates the exposure by changing the brightness control Aut...

Page 10: ...ven a left and right end of the PTZ range When the camera enters this area the name will be displayed on the screen which provides better orientation in surveillance application Up to 8 zones are supp...

Page 11: ...EXIT RESUME OFF SEQUENCE 002 RESET DELAY 020 ALARM CONTACT N C ALARM SETTING ARM SETTING RESUME SEQUENCE RESET DELAY ALARM CONTACT ENABLE WINDOW ALARM SETTING ARM SETTING Continue the function on the...

Page 12: ...IT EDIT SCAN LABEL LABEL PATTERN 1 BACK EXIT EDIT PATTERN LABEL LABEL ZONE 1 BACK EXIT EDIT ZONE LABEL LABEL BACK EXIT EDIT DOME LABEL DISPLAY SETUP ADVANCE SETTING PRESETS SCAN PATTERNS TOUR ZONES TI...

Page 13: ...1 0 0 0 0 0 1 1 0 0 0 0 1 1 0 1 1 0 0 0 0 0 1 0 1 0 0 0 1 1 0 0 0 1 0 0 0 0 1 1 1 0 0 0 1 1 0 1 0 1 0 0 0 0 1 0 0 1 0 0 1 1 0 0 1 1 0 0 0 0 1 1 0 1 0 0 1 1 0 1 1 1 0 0 0 0 1 ID ID Switchnumber Sw1 Swi...

Page 14: ...Max 40 sec Self Study Pattern Four Channel Alarm Inputs Normal Open Closing for Alarm One Channel Alarm Output IP Rating IP66 Normal Open Normal Close for Output Power Consumption 24V AC 30 VA Power S...

Reviews: