Okina USA SEIMW36T-V53DN Operation Manual Download Page 10

PATTERNS

PATTERN NUMBER

XX

PROGRAM PATTERN
RUN PATTERN
CLEAR PATTERN

EDIT PATTERN LABEL
BACK
EXIT

The Pattern-Tour is a custom-defined tour by recording user’s control action up to 180 sec per tour. This dome can
support up to 4 pattern tours.

PATTERN NUMBER:
PROGRAM PATTERN:

RUN PATTERN:
CLEAR PATTERN:
EDIT PATTERN LABEL:

Selected pattern tour

Record the tour. Enter this menu and start the tour recording, when finished,

Press[IRIS OPEN] to store.

Start the selected pattern tour

Delete the selected pattern

Assign the name of the pattern

Function Setting

Pattern

TOUR

---------------------------------------
TOUR

NUMBER

1

EDIT TOUR
RUN

TOUR

CLEAR TOUR
BACK
EXIT

A tour is a automated cruising through selected preset positions with individual speed and dwell time. This PTZ supports up
to 4 tours with 24 position each.

TOUR NUMBER:
EDIT TOUR:
RUN TOUR:
CLEAR TOUR:

Currently selected tour

Edit the selected tour

Start the selected tour

Delete the selected tour

Function Setting

Tour

EDIT TOUR

---------------------------------------
P0-S-TM P0-S-TM P0-S-TM

- 00
- 00
- 00
- 00
- 00

- 00

- 00

- 00

BACK

EXIT

00-0- 00 00-0- 00 00-0
00-0- 00 00-0- 00 00-0
00-0- 00 00-0- 00 00-0
00-0- 00 00-0- 00 00-0
00-0- 00 00-0- 00 00-0

00-0- 00 00-0- 00 00-0

00-0- 00 00-0- 00 00-0

00-0- 00 00-0- 00 00-0

Function Setting

Tour

Edit Tour

PO

S:
TM:

: The preset position being included in the tour. If there is no preset position stored,please define the

preset at first.

The velocity when PTZ moves to this preset, between low1 - high 8.

The dwell before the PTZ moves to next point. between 1-60 second

The ZONE function allows user to define a perimeter with a name tag. The perimeter is defined by given a left- and right-end
of the PTZ range. When the camera enters this area, the name will be displayed on the screen, which provides better
orientation in surveillance application. Up to 8 zones are supported.

ZONE NUMBER:
SET LEFT LIMIT:
SET RIGHT LIMIT:
CLEAR ZONE:
EDIT ZONE LABEL:

Currently selected zone

Set the left-end, press [IRIS OPEN] to store, or [IRIS CLOSE] to discard.

Set the right-end, press [IRIS OPEN] to store, or [IRIS CLOSE] to discard.

Delete the zone setting

Edit the name tag

ZONE

--------------------------------

ZONE NUMBER

1

SET LEFT LIMIT
SET RIGHT LIMIT
CLEAR ZONE

EDIT ZONE LABEL
BACK

Function Setting

Zones

The Time Running function is a scheduled start for predefined action, such as preset tour, scan tour ..etc. This dome
supports up to 4 schedules. Before setting this function, please make sure that the system time has been set correctly.

TIME CHANNEL:
START TIME:
END TIME:
RUNNING:

Currently selected schedule

Start time of the selected schedule

End of the schedule

Define the action to be started. Select None to deactive the function.

TIME RUNNING

--------------------------------

TIME CHANNEL

1

START TIME

00:00

END TIME

01.00

RUNNING

NONE

BACK
EXIT

Function Setting

Time Running

EDIT ZONE LABEL

---------------------------------------

BACK
EXIT

LABEL: ZONE -1

Function Setting

Zones

Edit Zone Label

Enter the zone name here.

The Window-Blanking function is use to protect the privacy in observed area, as this might be requested by
the law. It is also known as “Privacy Masking”, which cover the selected area with a blank window, depend on
modul how much Masking it has.

Currently selected window

Edit the current masking window

Activate the masking window

Dclear the selected masking window

WINDOW NUMBER:
EDIT WINDOW:
ENABLE WINDOW:
CLEAR WINDOW:

Window Blanking

WINDOW BLANKING

---------------------------------------
WINDOW NUMBER

01

EDIT WINDOW
ENABLE WINDOW

OFF

CLEAR WINDOW
BACK
EXIT

OSD

English

7

Summary of Contents for SEIMW36T-V53DN

Page 1: ...36x Wide Dynamic ICR IR PTZ Camera OPERATION MANUAL SEIMW36T V53DN OKINA...

Page 2: ...nent damage and avoids the warranty For indoor application with extrem wet condition or area contains water or high humidity use the outdoor model instead When the indoor PTZ get wet turn off the powe...

Page 3: ...Menu System Setting Edit dome label Initial Info Display Setup Motion Motion Advanced Setting Clear Password Setting Clock Setting Camera Setting IR CUT Filter Function Setting Presets Scan Pattern T...

Page 4: ...ID 4 Termination ON Use 4 Screws to fix not included Wall Mount Bracket optional accessory Reverse Mount Use 4 Screws to fix not included Change SETTING in OSD Mounting Use 4 Screws to fix not includ...

Page 5: ...cessary to consider the environmental in fluences when planning the installation If the transmission requires a larger distance you may use video balun or fiber transmitter to extend the distance Cont...

Page 6: ...ontrol Make sure that your controller device supports these functions Zoom in PAN Zoom out TILT The PAN and TILT function are mostly performed from the Joystick on the keyboard Please refer to the use...

Page 7: ...ect the desired character and RIGHT for next input Available characters appear in following order Use LEFT to move to previous character when edit In case you need to delete a character use the SPACE...

Page 8: ...LEARALLTOURS CLEARALLWINDOWS FACTORYDEFAULT RESTART CLEAR CLEAR ALL ZONES CLEAR ALL PRESET CLEAR ALL PATTERNS CLEAR ALL TOURS CLEAR ALL WINDOWS FACTORY DEFAULTS RESTART BACK EXIT The password function...

Page 9: ...erent environment In shutter mode the camea changes the shutter speed to regulate light Regulate the Iris openning to control the exposure Regulates the exposure by changing the brightness control Aut...

Page 10: ...ven a left and right end of the PTZ range When the camera enters this area the name will be displayed on the screen which provides better orientation in surveillance application Up to 8 zones are supp...

Page 11: ...EXIT RESUME OFF SEQUENCE 002 RESET DELAY 020 ALARM CONTACT N C ALARM SETTING ARM SETTING RESUME SEQUENCE RESET DELAY ALARM CONTACT ENABLE WINDOW ALARM SETTING ARM SETTING Continue the function on the...

Page 12: ...IT EDIT SCAN LABEL LABEL PATTERN 1 BACK EXIT EDIT PATTERN LABEL LABEL ZONE 1 BACK EXIT EDIT ZONE LABEL LABEL BACK EXIT EDIT DOME LABEL DISPLAY SETUP ADVANCE SETTING PRESETS SCAN PATTERNS TOUR ZONES TI...

Page 13: ...1 0 0 0 0 0 1 1 0 0 0 0 1 1 0 1 1 0 0 0 0 0 1 0 1 0 0 0 1 1 0 0 0 1 0 0 0 0 1 1 1 0 0 0 1 1 0 1 0 1 0 0 0 0 1 0 0 1 0 0 1 1 0 0 1 1 0 0 0 0 1 1 0 1 0 0 1 1 0 1 1 1 0 0 0 0 1 ID ID Switchnumber Sw1 Swi...

Page 14: ...Max 40 sec Self Study Pattern Four Channel Alarm Inputs Normal Open Closing for Alarm One Channel Alarm Output IP Rating IP66 Normal Open Normal Close for Output Power Consumption 24V AC 30 VA Power S...

Reviews: