Installation Procedure
2 - 3
OKIOFFICE 44
Service Manual, P/N 59276801
2.2
Site Selection
INSTALLATION
Precautions for Installation
(1) Fluctuation in line voltage
• 120V AC (102V to 127V)
• 230V AC (198V to 264V)
(2) Room temperature
50 to 90 degrees Fahrenheit (10 to 32 degrees Celsius)
(3) Humidity
20 to 80% RH
(4) Operating environment
Pressure: Equivalent to altitude of 2500 m and below.
(5) Exposure
Within five minutes at luminous intensity 2,000 lux (with the stacker cover opened).
(6) Required space for installation
The facsimile requires adequate space for safety and good operability.
(7) Levelness of installation surface
1 degree maximum.
(8) Other requirements
Avoid installing in any of the following places:
• A place exposed to direct sunlight
• A place near a heat source or exposed to vibration
• A dusty place
• A place in the atmosphere of acid gas, or steam etc.,
• A place exposed to quick temperature changes
Summary of Contents for OKIOFFICE 44
Page 2: ...All specifications are subject to change without notice Service Manual OKIOFFICE 44 59276801...
Page 135: ...Disassembly 4 6 OKIOFFICE 44 Service Manual P N 59276801 Whole Unit Picture FX048 CP4 1 Fig 01...
Page 329: ...Illustrated Parts List D 6 OKIOFFICE 44 Service Manual P N 59276801 Section 2 Printer Unit...
Page 331: ...Illustrated Parts List D 8 OKIOFFICE 44 Service Manual P N 59276801 Section 3 Operator Panel...
Page 351: ...Illustrated Parts List D 28 OKIOFFICE 44 Service Manual P N 59276801 Section 12 Cables...
Page 357: ...Board Layout E 2 OKIOFFICE 44 Service Manual P N 59276801 MEM eps E 2 MEM PCB...
Page 358: ...Board Layout E 3 OKIOFFICE 44 Service Manual P N 59276801 TEL U eps E 3 TEL U PCB...
Page 359: ...Board Layout E 4 OKIOFFICE 44 Service Manual P N 59276801 Hook eps E 4 Hook PCB...
Page 388: ...OKIOFFICE 44 Service Manual Part Number 59276801 Printed in the USA...