– 61 –
11-3. USB / PoweredUSB Interface Model
ON
ON
OFF
OFF
DIP-SW 1
Switch
Function
ON
OFF
1-1
Emulation
STAR line mode
ESC/POS mode
1-2
STAR line mode
Reserved
Always ON
ESC/POS mode
Resolution correc-
tion
203 dpi
180 dpi
1-3
Should not be changed (Should be set to on)
1-4
Sensor adjustment
Invalid
Valid
1-5
USB mode
Printer class
-
1-6
Handshaking conditions (conditions for
BUSY)
Offline or receive
buffer full
Receive buffer full
1-7
ASB Function *1)
Invalid
Valid
1-8
Star Line Mode
NSB Function *2)
Valid
Invalid
ESC / POS Mode
Reserved
Should not be changed (Should be set to on)
1-9
Low-power consumption mode *3)
Invalid
Valid
1-10
Validation status in standby condition printing
Opening the platen
Closing the platen
*3) The settings will be invalid (always low-power consumption mode) when a Powered
USB
is being used.
The factory settings of DIP switch are all on.
DIP-SW 2
Switch
Function
ON
OFF
2-1~2-4
Always ON
Should be set to on
The factory settings of DIP switch are all on.
No. 1 2 3 4 5 6 7 8
No. 1 2 3 4
9 10
DIP-SW 1
DIP-SW 2