Page: 101
Service Guide OL1200
Chapter 6 Troubleshooting Procedures
The printer does not work normally after being turned on.
Is
message shown in the LCD display (for less than 1 second)?
No
Is the AC cable connected properly?
No
Connect the cable properly.
No
Is the message (16 columns display only on the top row ) shown in the LCD
display?
Yes
Replace the Control board.
Yes
Are the following voltages applied to the corresponding pins of the POWER
connector on the Control board? (For the measuring points, see Fig. 6-1.)
Pin 15: 8V, Pin 16: +8V, Pins 19, 20: +30V
Pins 21, 22, 26-29: 0V, Pins 23-25: +5V
No
Remove the AC cable. Set the POW switch to the ON position.
Measure the resistance between L and N pins of the AC inlet using a
multimeter. Is there continuity between L and N pins (normal resistance:
554 ký)? (For measuring points, see Fig. 6-2.)
No
Replace the fuse F1 or the Power/sensor board
Yes
Are POWER connector and FRONT connector (white, 9-pin connector)
for CN3 on the Power/sensor board, CN8 on the Driver board, and the
Control board made properly.
No
Connect the connectors properly.
Yes
Are the following voltages applied to CN3 connector of the Power/sensor
board? (For measuring points, see Fig. 6-3.)
Pins 16, 17: +30V, Pins 8-10, 14, 15: 0V
Pin 20: 8V, Pins 11-13: +5V, Pin 21V: +8V
No
Replace the Power/sensor board.
Yes
Replace the Driver board.
Is the printer recovered?
Summary of Contents for OL1200
Page 63: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 65: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 95: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 104: ......
Page 121: ...Page 79 Service Guide OL1200 Chapter 4 Adjustment Engine maintenance mode menu system...
Page 156: ...Fig 6 1 Connector and Pin Location Fig 6 2 Measurement by a Multimeter...
Page 161: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 188: ......
Page 192: ...Page 122 Service Guide OL1200 Chapter 7 Wiring Diagram 7 2 PCB Layout 1 Control board AOLM...
Page 194: ...Page 123 Service Guide OL1200 Chapter 7 Wiring Diagram 7 3 Resistance Check...
Page 198: ...Page 125 Service Guide OL1200 Chapter 8 Parts List 8 PARTS LIST Figure 8 1 Printer Unit...
Page 205: ...Page 127 Service Guide OL1200 Chapter 8 Parts List Front Feeder Unit...
Page 230: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 271: ...Partner Exchange BPX for any updates to this material http bpx okidata com...