Backfeed Enable
Command Structure
<ESC>CEa
a =
0
Disables
Backfeed.
1
Enables Backfeed.
Example: <ESC>CE1
Placement: This command should be sent in a separate data stream.
Default:
Last
setting.
Command Function
To select the top-of-label sensing method.
Input to Printer
<ESC>A
<ESC>CE1
<ESC>Z
Printer Output
There is no printer output as a result of this command.
Special Notes
1.
When Backfeed is enabled, the printer will feed the last label of a print job
forward to the dispense/cut position. Upon the receipt of the next print job, it
will retract the label to the first print line position before printing.
2.
The setting can be saved to printer non-volatile memory.
3.
The setting becomes ineffective once cutter or dispenser is enabled.
87