4.
Unhook the tab [1], remove the
ozone ventilation fan motor [2].
7.3.25
Exit tray cooling fan motor (FM4)
1.
Remove the IR unit.
See P.
85
2.
Remove the auto document feeder unit
.
See P.
87
3.
While pressing down the plate [1],
move the spring assy [2] in the direc-
tion of the arrow.
4.
Remove the screw [1], and remove
the arm unit [2].
5.
Repeat the steps 3 and 4 to remove the arm unit located on the opposite side.
A034F2C045DA
[1]
[2]
A034F2C105DA
[1]
[2]
A034F2C106DA
[1]
[2]
6.
Remove six screws [1], and remove
the IR unit lower cover assy [2].
7.
Remove the connector [1] and move
the fixing members [2] in the direc-
tion of the arrow to remove the exit
tray cooling fan motor [3].
7.3.26
Tray1 media feed solenoid (SD1)
1.
Remove the media feed driving unit.
See P.
84
2.
Remove the screw [1], and remove
the tray1 media feed solenoid [2].
NOTE
• Use care not to lose the two
springs.
A034F2C107DA
[1]
[1]
[2]
A034F2C108DA
[1]
[2]
[3]
A034F2C054DA
[1]
[2]
6.3.26
Tray1 media feed solenoid (SD1)
6.3.25
Exit tray cooling fan motor (FM4)