44292401TH Rev.1
85 /
Oki Data CONFIDENTIAL
MAINTENANCE
4.
Remove two screws [1] and open the
front cover [2] to remove the media
feed tray unit [3].
5.
Disconnect the connector [1] of the
tray1 media feed solenoid.
6.
Remove the tapes [1] at two posi-
tions.
A034F2C090DA
[1]
[2]
[3]
A034F2C029DA
[1]
A034F2C030DA
[1]
7.
Remove four screws [1], and remove
the media feed driving unit [2].
7.3.17
IR unit
1.
Remove the rear cover.
See P.
76
2.
Remove the right cover.
See P.
76
3.
Remove the left cover.
See P.
76
4.
Remove two flat cables [1] (P6, P7)
from the MFP board and remove
them from the guide [2].
5.
Remove three connectors [3] (P1,
P2, P4) from the MFP board.
Remove their harness from the har-
ness guide [4].
A034F2C031DA
[1]
[2]
[1]
A034F2C091DA
[1]
[2]
[3]
[4]
6.3.17
IR unit
Summary of Contents for MC160MFP
Page 1: ...MC160MFP Maintenance Manual 011710A...
Page 18: ...44292401TH Rev 1 17 Oki Data CONFIDENTIAL MC160n Main body THEORY OF OPERATION...
Page 55: ...44292401TH Rev 1 54 Oki Data CONFIDENTIAL Auto Document Feeder Unit THEORY OF OPERARTION...
Page 61: ...44292401TH Rev 1 60 Oki Data CONFIDENTIAL MC160n Main body FIELD SERVICE...