41956001TH Rev.1
113 /
Oki Data CONFIDENTIAL
P: No. of test print pages (unit: page)
U: Temperature of top heater [Set value] (unit: Celsius)
L: Temperature of bottom heater [Set value] (unit: Celsius)
T: Environment temperature (unit: Celsius)
H: Environment humidity (unit: percent)
•
The display changes by pressing the
3
3
3
3
3
key.
•
The following messages appear during print operation.
YTR, MTR, CTR, KTR are values of the set transfer voltage. (unit: KV)
•
The display changes by pressing the
3
3
3
3
3
key.
YR, MR, CR, KR are transfer rollers of each color values of the set transfer voltage. (unit:
KV)
5. Repeat Steps 2 to 4 as required.
6. Press the
4
4
4
4
4
key to end the test. (Status returns to that described in 1.)
KTR=*.**KV YTR=*.**KV
MTR=*.**KV CTR=*.**KV
KR=*.**KV YR=*.**KV
MR=*.**KV CR=*.**KV
P=*** T=*** U=***[###]
H=***% L=***[###]
Summary of Contents for C9300 Series
Page 48: ...41956001TH Rev 1 48 Oki Data CONFIDENTIAL 3 2 Parts Layout Figure 3 1 ...
Page 49: ...41956001TH Rev 1 49 Oki Data CONFIDENTIAL Figure 3 2 Top Cover Assy ...
Page 50: ...41956001TH Rev 1 50 Oki Data CONFIDENTIAL Figure 3 3 Printer Unit 1 2 ...
Page 51: ...41956001TH Rev 1 51 Oki Data CONFIDENTIAL Figure 3 4 Printer Unit 2 2 ...
Page 52: ...41956001TH Rev 1 52 Oki Data CONFIDENTIAL Figure 3 5 Cassette Guide Assy L R ...
Page 53: ...41956001TH Rev 1 53 Oki Data CONFIDENTIAL ...
Page 54: ...41956001TH Rev 1 54 Oki Data CONFIDENTIAL A B C D E A B C D E Figure 3 6 Duplex Unit ...
Page 112: ...41956001TH Rev 1 112 Oki Data CONFIDENTIAL Pattern 5 Pattern 6 Pattern 7 ...
Page 178: ...41956001TH Rev 1 178 Oki Data CONFIDENTIAL 37 26 33 38 32 39 38 31 34 35 36 27 Figure 8 1 3 3 ...