5.1.2.4 Motor/Clutch Test
This self-diagnosis routine is used to test the motor and clutch.
1. Continue to press the [MENU+] and [MENU-] keys until “Motor & Clutch Test”
appears at the top of the display and the operation enters the self-diagnosis (Level 1)
mode.
The [MENU+] key = Increment Test Item / the [MENU-] key = Decrement Test Item.
2. The following message appears when the [ENTER] is pressed. The suitable location
of the unit to be tested as shown in Table 5-2 will appear at the bottom of the
display.
Press the [MENU+] and [MENU-] keys.
The [MENU+] key = Increment Test Item / the [MENU-] key = Decrement Test Item.
3. Press the [ENTER] key to start the test. The name of the unit will start blinking. Then
the applicable unit will drive for 10 seconds.
Note!
After driving for 10 seconds, it will return to State 2. The drive will start
again by re-pressing the applicable switch.
• To drive the applicable unit, there is a need to clear the drive limitational conditions
indicated in Table 5-2. Launching a state drive that doesn’t clear the limitation con-
ditions is invalid. When this happens the clear information is displayed at the bot-
tom of the display.
• The clutch solenoid generally repeats ON/OFF with regular printer driver. (models
that do not drive independently due to its mechanical structure will come be driven
by a motor.)
4. Press the [CANCEL] key to stop the applicable unit drive. (maintain the display of the
applicable unit, at this time)
5. Accordingly repeat Steps 2 to 4.
6. Press the [BACK] key to end the test. (Returns to state 1)
MOTOR & CLUTCH TEST
PK – ID MOTOR
Summary of Contents for C910
Page 1: ...Oki Data CONFIDENTIAL Model X Maintenance Manual 032007A...
Page 13: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 12 6 Finisher Unit 5 Tray except for China...
Page 94: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 93 4 2 Parts Layout MAIN ViewA Next page C910 Only...
Page 95: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 94 600dpi 1200dpi Air Flow Air Flow Air flow ViewA...
Page 96: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 95 Printer Unit 120V 230V 1 2 See next page...
Page 97: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 96 Printer Unit 120V 230V 2 2 A A...
Page 98: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 97 Plate Assy Power_120V 230V...
Page 99: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 98 Base Assy 1 2...
Page 100: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 99 Base Assy 2 2 A A...
Page 101: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 100 Side R Assy...
Page 102: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 101 Side F Assy C910 Only...
Page 103: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 102 Duct Drive Assy...
Page 104: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 103 FDR Unit Regist A A C C B B...
Page 105: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 104 FDR Unit MPT A A 2...
Page 106: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 105 Eject Assy...
Page 107: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 106 Plate Top Assy...
Page 108: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 107 Job Offset Assy...
Page 109: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 108 Basket Assy...
Page 119: ...Oki Data CONFIDENTIAL 44043511TH Rev 2 118 Plate Top...