OAC 2221
Description
Symbol
Value
Unit
Sound power level
L
WA
65
dB
Global warming potential *
GWP
2088
kg CO
2
eq.
Rated capacity for cooling
P
rated
for
cooling
2.3
kW
Rated capacity for heating
P
rated
for
heating
n/a
kW
Rated power input for cooling
P
EER
0.9
kW
Rated power input for heating
P
COP
n/a
kW
Rated Energy efficiency ratio
EERd
2.6
-
Rated Coefficient of performance
COPd
n/a
-
Power consumption in thermostat-off mode
P
TO
0.8
W
Power consumption in standby mode
P
SB
0.4
W
Electricity consumption of single/double duct products
(indicate for cooling and heating separately)
DD: Q
DD
SD: Q
SD
0.9
DD: kWh/a
SD: kWh/h
Contact details for obtaining more information
Imtron GmbH
Wankelstraße 5, 85046 Ingolstadt, Germany
The rated cooling capacity was tested under following conditions:
Cooling operation
Indoor
35 °C (DB)
24 °C (WB)
*
Note:
• This product contains fluorinated greenhouse gas (hermetically sealed) which is dangerous for the
environment and contributes to global warming if released to the atmosphere.
• Refrigerant type: R410A
• Global warming potential (GWP): 2088
• Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential
(GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the
atmosphere.
• This product contains a refrigerant fluid with a GWP equal to 2088. This means that if 1 kg of this
refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 2088
times higher than 1 kg of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant
circuit yourself or disassemble the product yourself and always ask a professional.
• Energy consumption 0.9 kWh per 60 minutes, based on standard test results. Actual energy
consumption will depend on how the product is used and where it is located.