B905-FTN-TA MANUAL
Address : #181 GONG DAN-DONG, GUMI, GYEONG BUK, KOREA Page
10
/
17
TEL : 82-54-468-7063 / FAX : 82-54-461-8368
http://www.ohsungec.com/
c)
If an user presses [DOWN] key, the remote control will send [VOL+] code of the next
Soundbar code set on every [DOWN] key press.
d)
If an user presses and holds [DOWN] key, the remote control will send [VOL+] code of
the next Soundbar code set every 2 seconds.
e)
If the end of the DB is reached, the LED will blink 3 times.
If the [DOWN] key is pressed and held, the remote control will repeat [VOL+]
commands another cycle.
f)
In set-up mode, user can test the [VOL+], [VOL-], and [Mute] keys.
g)
If OK key is pressed, the changed setting value is saved and the remote control exits the
set up mode. Then the remote control will blink the LED three times to let user know
that remote control was exiting set-up mode.
3.10 – Factory Reset
a)
Press [MENU] + [STOP] key for 3 seconds.
b)
The Factory reset will be initialized as LED blinks 5 times.
c)
Factory Reset initializes the TV settings.
d)
RCU deleting the existing pairing table and works in IR.
3.11 – Low Voltage Indicate
a)
If the battery power reaches up to (2.0V±0.2V) and any key is pressed and released,
LED will blink 10 times to indicate that the battery power is low.
3.12 – IR Protocol (Apple IR Protocol)
a)
This protocol uses the NEC Infrared remote control transmission format. Each packet in
the NEC format contains up to 32 bits of binary data.
b)
IR Carrier
- Carrier frequency = 38 kHz.
- Recommended duty cycle = 0.3 or 30%
c)
Standard Packet