3 Energy saving mode
Internal fan runs in conjunction with cooling operation.
Energy saving is realized by stopping the internal fan when cooling operation is stopped in a cool season like
winter.
The values in have been set as default.
4 Energy saving mode 3
This mode is used when periodic interval in cooling operation is desired for energy saving in case the internal
temperature goes down below the set value but not reach the differential value. Cooling and shutdown times are
set by the parameter t an t . The values in have been set as default.
*Cooling operation time when external fan and compressor are running intermittently 7 minutes
*Shutdown time of external and compressor 3 minutes
【
Caution
】
・
There is a risk of causing local temperature rise hot spot as the air is not circulated by internal fan.
・
or protection of refrigerant circuit, internal fan stops in 5 minutes after cooling operation has stopped.
【
Caution
】
・
In this mode, the internal temperature can rise above the set value as compressor stops unconditionally by
the set time. If heat value inside the enclosure is high, the internal temperature can rise above the high
temperature alarm temperature.
・
If the internal temperature fails to reach the set value within the set period, cooling operation will be
continued until the internal temperature goes down to the set value to prevent excessive temperature rise.
・
or protection of refrigerant circuit, internal fan stops in 5 minutes after cooling operation has stopped.
・
Internal fan runs continuously when the internal temperature goes up above the differential temperature.
High temperature alarm setting
45
℃
)
Setting temperature 35
℃
Differential temperature 3
℃
Differential temperature 3
℃
External fan, compressor
ON
O
Internal fan
ON
O
External fan, compressor
ON
O
Internal fan
ON
O
Setting temperature 35
℃
Summary of Contents for COOL CABI OCA-H300BC-AW2
Page 3: ...3 20 50 85 RH 0 60 85 RH R1234yf...
Page 4: ...4 2 1...
Page 6: ...6 8 9 COOLCABI...
Page 7: ...7 8 2 2 9 COOLCABI COOLCABI COOLCABI...
Page 12: ...12 30 ON OFF 1 6 ON OFF ON OFF 13 No Up UP Down Down Set...
Page 15: ...15 35 5 35 30 4 E 3 30 1 30 5 35 30 35 30 ON OFF ON OFF ON OFF ON OFF...
Page 16: ...16 7 3 5 5 45 35 30 30 ON OFF ON OFF ON OFF ON OFF 35...
Page 30: ...30 OCA H350BCD AW2 OCA H700BCD AW2 OCA H1300BCD AW2 OCA H2300BCD AW2 1...
Page 60: ...60 20 50 85 RH 20 60 85 RH R1234yf LFL 25 OFN...
Page 61: ...61 2 1...
Page 63: ...63 30 65 66 COOLCABI...
Page 64: ...64 65 2 2 66 COOLCABI COOLCABI COOLCABI...
Page 69: ...69 30 ON OFF 1 6 ON OFF ON OFF 70 Up UP Down Down Set...
Page 72: ...72 35 5 35 30 4 E 3 30 1 30 5 35 30 35 30 ON OFF ON OFF ON OFF ON OFF...
Page 73: ...73 t1 t2 7 3 5 5 45 35 30 30 ON OFF ON OFF ON OFF ON OFF 35...
Page 87: ...87 OCA H350BCD AW2 OCA H700BCD AW2 OCA H1300BCD AW2 OCA H2300BCD AW2 1...