background image

 

3-1 

3

 BASIC COMPOSITION OF TREND DISPLAY 

 

3.1 Trend display 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group tab 
The group display can be changed by selecting “

Group tab”. 

 

Channel tab 
Selected “

Channel tab” moves at the right of the channel, and displays the corresponding width 

of the scale in “

Trend display area”. 

 

Trend display area 
The trend data recorded can be displayed. 

 

Scale display 
The scale width set each channel can be displayed. 
When "

Scale display" is double-clicked, the scale can be set with the manual. 

(Refer item 5.5 for manual setting of a scale.) 

 

Unit 
The unit set each channel can be displayed. 

 

Cursor 
This date of line for measured value is displayed on the “

Measured value display”.

 

 

Cursor date 
The date that the “

Cursor” indicates is displayed. 

Tool bar 

 
 
 

Group tab 

 
 
 

Channel tab 

 
 
 

Scale display 

 
 
 

Unit 

 
 
 

Cursor date 

 
 
 

Message mark 

 
 
 

Comment mark 

 
 
 

Alarm occurred / 

cleared mark 

Scroll bar 

 
 
 

Measured 

  value display 
 
 
 

Time (H : M : S) 

24-hour display

 

Trend   

display area 

 
 

Cursor 

 
 
 

Summary of Contents for VM7000A

Page 1: ...INSTRUCTION MANUAL FOR VM7000A VM7000B PAPERLESS RECORDER WXPVM70mnA0101E December 2015 Rev 7 Copyright 2009 2015 Ohkura Electric Co Ltd All Rights Reserved Graficzne rejestratory temperatury VM7000A...

Page 2: ...rovided that the software is only installed in the corporation that purchased the product Article 2 Limitations on Duplication The customer may make to copy of this software for backup purposes only A...

Page 3: ...the file 2 4 3 BASIC COMPOSITION OF TREND DISPLAY 3 1 3 1 Trend display 3 1 3 2 Instantaneous value 3 3 3 3 Event Summary 3 4 4 OPERATION METHOD 4 1 4 1 File 4 1 4 2 View 4 1 4 3 Zoom 4 2 4 4 Event Co...

Page 4: ...tallation 1 Instruction Manual which is installed above CD ROM 1 4 Recommended operating environment Microsoft Windows XP Vista 7 8 8 1 32bit 64bit The Viewer is not run on Windows 95 98 2000 NT and M...

Page 5: ...rk may need to be installed In that case install software after installing NET Framework In the case of Windows8 environment connectable with the Internet is required for installation of NET Framework...

Page 6: ...2 1 2 BASIC OPERATION 2 1 Start Select Programs VM7000A_B Data Viewer from the Start menu...

Page 7: ...de in the SD card The SD card where the file is preserved is connected with the personal computer an arbitrary file is selected from Recorder Data and it copies it to the personal computer The SD card...

Page 8: ...of three Trend screen Instantaneous value and Event Summary Instantaneous value and Event Summary can only be changed Display Non display from View of menu And Layout can be changed from same Item Ref...

Page 9: ...lect File Save display state or Save As The same operation can be done even by the Save of tool bar Refer item 3 1 for the tool bar 2 The currently screen displayed to select Save display state is pre...

Page 10: ...h set each channel can be displayed When Scale display is double clicked the scale can be set with the manual Refer item 5 5 for manual setting of a scale Unit The unit set each channel can be display...

Page 11: ...bar cannot be changing Alarm occurred cleared mark The alarm occurred or cleared while recording is marked and displayed Message mark The message occurred while recording is marked and displayed Comme...

Page 12: ...screen is up to 1000 To view data in excess of 1000 select the Page switch Scroll bar Measured values that overflow in the margin can be displayed by doing Scroll bar in the slide Time Measured value...

Page 13: ...Event Summary Event tab The event occurred while recording is changed Event display area The event occurred while recording is displayed Time The occurred event is displayed Event display area Event t...

Page 14: ...d screen Print Preview Display the print preview 2 Exit End the Data Viewer 1 Refer item 2 3 for details 2 Refer item 5 for details 4 2 View View Item Setting contents Realtime Trend Display the Realt...

Page 15: ...ent Delete the comment is selected Alarm disp Select the Display non display of alarm mark on the trend display area Message disp Select the Display non display of message mark on the trend display ar...

Page 16: ...ly when there is plurals window Tile windows Vertically It displays it to tile vertical when there is plurals window Tile windows Horizontally It displays it to tile horizontal when there is plurals w...

Page 17: ...tputted to CSV Select time Arbitrary range is outputted to CSV Initial value is the range of All data Addition of header information Header information such as channel information and group informatio...

Page 18: ...a File record cycle Refer item 7 19 of Paperless Recorder Manual for File record cycle dm file can not unite If Unites file of a dm file is performed a display will be switched to the next dm file or...

Page 19: ...ss and Example of setting telecommunication facility for the details Example of setting IP Address Windows XP First of all Start menu Control Panel Network connection is selected And Local area connec...

Page 20: ...Windows 8 From the Setting open Control Panel and select Network and Sharing Center When you select Connections under View your active networks Local Area Connection Status window appears Click the P...

Page 21: ...the IP address is 10 10 40 3 and the subnet mask is 255 255 255 0 When you set a DNS server address an IP address a subnet mask and a default gateway Ask a network administrator and set up carefully W...

Page 22: ...as Paperless Recorder FTP In this case User is set as user OK is selected and the setting is preserved Refer item 8 6 and 8 10 of Paperless Recorder manual for the Ethernet1 and FTP Moreover a maximu...

Page 23: ...this case the file can be downloaded by selecting the dm file in the Data folder and pushing Download The file which can be referred to with a Data Viewer is dm file or dmt file In order to read dm f...

Page 24: ...setting telecommunication facility for the details Main record start stop button It supports since software version 1 20 The recorder start main recording and stop main recording Sub record start sto...

Page 25: ...s changed Comm status The current communicating state is displayed Green Data Viewer and a recorder are communicating Black Data Viewer and a recorder are not communicating Measurement Cycle The measu...

Page 26: ...name set up with the recorder is displayed Channel Tag display switch The display of channel No and a tag is switched Usable range The scale range to be used is chosen from Auto and a Manual Auto Sett...

Page 27: ...tch is switched It can be operated only when the Print type of option setting is a Page unit Refer next page for option Page No The current page number is added to the record data to print Guide Tag n...

Page 28: ...outside of a trend by option Refer Option for option Measured value display area The measured value of the position chosen with Cursor is displayed Move of cursor cannot be performed in a print previe...

Page 29: ...p a display un displaying of Page No Setting the guide It sets up a display un displaying of Guide Setting the graph title The name of the graph title displayed on graph title is set up Setting the X...