OHAUS TD32PE Instruction Manual Download Page 36

EN-34

3

000 Series Indicators

 Marking 

Standard

This product conforms to the EMC Directive 2004/108/EC and the Low Voltage Directive 2006/95/EC. 
The complete Declaration of Conformity is available online at www.ohaus.com/ce.                                                       

8.4   Compliance

Compliance to the following standards is indicated by the corresponding marking on the product.

Disposal 

In conformance with the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment 

(WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside 

the EU, per their specific requirements. 

The Batteries Directive 2006/66/EC introduces new requirements from September 2008 on removabil

-

ity of batteries from waste equipment in EU Member States. To comply with this Directive, this device 

has been designed for safe removal of the batteries at end-of-life by a waste treatment facility.
Please dispose of this product in accordance with local regulations at the collecting point specified for 

electrical and electronic equipment. 

If you have any questions, please contact the responsible authority or the distributor from which you 

purchased this device. 

Should this device be passed on to other parties (for private or professional use), the content of this 
regulation must also be related. 

For disposal instructions in Europe, refer to www.ohaus.com, choose your country then search for 
WEEE.

Thank you for your contribution to environmental protection.

FCC Note

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC 
Rules.  These limits are designed to provide reasonable protection against harmful interference when the equipment is operated 
in a commercial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed 

and used in accordance with the instruction manual, may cause harmful interference to radio communications.  Operation of 

this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the 

interference at his own expense.

Industry Canada Note

This Class A digital apparatus complies with the Canadian ICES-003.

Cet appareil numérique de la classe A est conforme à la Norme NMB-003 du Canada.

ISO 9001 Registration

In 1994, Ohaus Corporation, USA, was awarded a certificate of registration to ISO 9001 by Bureau Veritus Quality International 

(BVQI), confirming that the Ohaus quality management system is compliant with the ISO 9001 standard’s requirements.  

 

On May 21, 2009, Ohaus Corporation, USA, was re-registered to the ISO 9001:2008 standard.

  

   

For disposal instructions in Europe, refer to www.ohaus.com/weee.

    

   Thank you for your contribution to environmental protection.

 

  

FCC Note

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC 

Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This 

equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not 

occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can 
be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:
• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

Industry Canada Note

This Class B digital apparatus complies with the Canadian ICES-003. 

Cet appareil numérique de la classe B est conforme à la Norme NMB-003 du Canada.

Summary of Contents for TD32PE

Page 1: ...i 3000 Series Indicators Instruction Manual TD32PE Indicator...

Page 2: ...ii...

Page 3: ...icator EN 10 2 2 4 RS232 Interface Cable to Indicator Optional EN 10 2 3 Internal Connections EN 11 2 3 1 Opening the Housing EN 11 2 3 2 Jumper Connections EN 11 3 SETTINGS EN 12 3 1 Menu Structure E...

Page 4: ...out EN 20 3 6 Mode Menu EN 21 3 6 1 Reset EN 21 3 6 2 Parts Counting Mode EN 21 3 6 3 End Mode EN 21 3 7 Unit Menu EN 21 3 7 1 Reset EN 21 3 7 2 Kilogram Unit EN 21 3 7 3 Gram Unit EN 21 3 7 4 Pound U...

Page 5: ...6 1 Weighing EN 26 4 6 2 Parts Counting EN 26 4 6 3 Totalization EN 27 5 SERIAL COMMUNICATION EN 28 5 1 Interface Commands EN 28 5 2 Output Format EN 28 5 3 Printout Examples EN 29 6 LEGAL FOR TRADE E...

Page 6: ...ut the product Warning Symbols General Hazard Electrical Shock Hazard 1 2 Safety Precautions Verify that the AC adapter s input voltage range and plug type are compatible with the local AC power to be...

Page 7: ...TD32PE Indicator Item Description 1 Front Housing 2 Control Panel 3 Power Receptacle 4 Load Cell Cable Connector 5 RS232 Connector optional 6 Data Label 7 FCC Information 8 Rear Housing 9 Mounting Tra...

Page 8: ...tion 1 Power Connector J1 2 Battery Connector J9 3 Option Connector J2 4 LFT Switch 5 4 6 Lines Sense Jumper W1 located on the other side of PCB 6 Load Cell Connector J4 7 4 6 Lines Sense Jumper W2 lo...

Page 9: ...Gram symbols 2 Battery function symbol 3 TARE Menu button 4 FUNCTION Mode button 5 Accumulation Symbol 6 NET function symbol 7 PRINT Units button 8 PCS function symbol 9 Stable weight Symbol 10 ON ZER...

Page 10: ...ng Unit Mode Allows changing the application mode Press and hold allows scrolling through modes Menu Enter the User menu Menu Function Short Press Yes Accepts the current setting on the display No Adv...

Page 11: ...2 1 Scale Base to Indicator Connect the load cell cable to the indicator as shown below 2 1 Note To connect TD32PE to other bases a loadcell connector needs to be soldered as shown above 2 2 2 AC Powe...

Page 12: ...e will disappear The indicator can operate for up to 80 hours on a fully charged battery During battery operation a flashing triangle above the battery function symbol indicates the battery is low and...

Page 13: ...includes sense wires Jumpers W1 and W2 must be opened Note 6 wire load cell setting is default After wiring is completed and jumpers are in place replace the indicator housing screws Figure 2 2 Jumpe...

Page 14: ...N ON PARITY 0 001 20 2d TOTALIZE GRAM 7 EVEN POWER ON UNIT 5d OFF OFF 7 ODD AUTO FILTER ON ON 7 NONE GRAM LOW END MODE LB 8 NONE KILOGRAM MED OFF STOP ZERO RANGE HI ON 1 0 AZT END UNIT 2 2 OFF HANDSHA...

Page 15: ...Allows entry into the displayed menu Accepts the displayed setting and advances to the next menu item No Skips by the displayed menu Rejects the displayed setting or menu item and advances to the nex...

Page 16: ...tion Linearity calibration uses 3 calibration points The first calibration point is established with no weight on the scale The second calibration point is established at approximately half capacity T...

Page 17: ...gravity Attention Changing the GEO Factor alters the calibration The GEO value was set at the factory and should only be changed by an authorized manufacturer s representative or certified veriricati...

Page 18: ...4 13 13 12 12 11 11 10 40 05 41 12 16 15 15 14 14 13 13 12 12 11 11 41 12 42 19 16 16 15 15 14 14 13 13 12 12 11 42 19 43 26 17 16 16 15 15 14 14 13 13 12 12 43 26 44 32 17 17 16 16 15 15 14 14 13 13...

Page 19: ...used for the first time enter this menu to set the Capacity and Graduation 3 4 1 Reset Reset the Setup menu to the factory defaults No not reset Yes reset NOTE If the Legal for Trade switch is switche...

Page 20: ...20 25 30 40 50 60 75 100 120 150 200 250 300 400 500 600 750 1000 1200 2500 0 1 0 2 0 5 1 5 10 15 20 25 30 40 50 60 75 100 120 150 200 250 300 400 500 600 750 1000 1200 1500 3000 0 1 0 2 0 5 1 5 10 15...

Page 21: ...Range 0 5d 1d 2d 5d Filter Lo Med Hi Auto Zero Tracking Off 0 5d 1d 3d Sleep Off On Light HI Med Low Auto Off Off 1 5 10 min Expand Off On End Readout Exit READOUT menu 3 5 1 Reset Set the Readout men...

Page 22: ...minal sleep functionality OFF Terminal will not sleep ON Terminal will sleep 3 5 7 Auto Off Set the automatic shut off functionality OFF disabled 1 powers off after 1 minute of no activity 5 powers of...

Page 23: ...the desired units Default settings are bold 3 7 1 Reset Set the Unit menu to the factory defaults NO not reset YES reset Reset No Yes Kilograms Off On Grams Off On Pounds Off On End Unit Exit UNIT men...

Page 24: ...ple Single Feed Line Feed 4 Line Feed Form Feed End Print Exit PRINT menu 3 8 1 Reset Set the Print menu to factory defaults NO not reset YES reset a 3 8 Print Menu appears only with RS232 option inst...

Page 25: ...mediately ON values are only printed when the stability criteria are met 3 8 4 Stop Bit Set the number of stop bits 1 1 stop bit 2 2 stop bits 3 8 8 Content Select the additional content of the printo...

Page 26: ...ayout criteria FORMAT Multi mutliple lines are printed Single single line is printed FEED Line move paper up one line after printing 4 Lines move paper up four lines after printing Form move paper to...

Page 27: ...urn the Indicator off press and hold the ON ZERO Off button until OFF is displayed 4 2 Zero Operation Zero can be set under the following conditions Automatically at Power On initial zero Semi automat...

Page 28: ...or sending the data to a computer requires that the communication parameters in the Print Menu are set refer to Section 3 8 Press the PRINT Units button to send the displayed data to the communication...

Page 29: ...Totalization or adds the new displayed value to the accumulated total and displays the new total value The Accum indicator will blink when the value is shown Display accumulated data To display the a...

Page 30: ...Zero button T Same as pressing Tare button xT Download Tare value in grams positive values only Sending 0T clears tare if allowed PU Print current unit g kg lb PCS xU Set scale to unit x 1 g 2 kg 3 lb...

Page 31: ...4 KG G Gross value line If Print Content Gross is ON and a tare value is entered 11 11 KG N Net value line If Print Content Net is ON and a tare value is entered 1 22 KG T Tare value line If Print Con...

Page 32: ...ing menu settings cannot be changed Span Calibration Linearity Calibration Calibration Unit GEO Capacity Graduation Zero Range Stable Range AZT Modes Units To enable editing of these menu settings ret...

Page 33: ...ng PCS display Busy message Displayed during tare setting zero setting printing NO Action not allowed message Function not executed Battery icon flashing Low Battery error Battery is empty CAL E Calib...

Page 34: ...2 Operating Temperature Range 10 C to 40 C 14 F to 104 F Housing Dimensions W x D x H 210 x 168 x 80 mm 8 27 x 6 61 x 3 15 in Net Weight 1 4 kg 3 1 lb Shipping Weight 2 4 kg 5 3 lb Shipping Dimensions...

Page 35: ...EN 33 3000 Series Indicators 8 3 Drawings and Dimensions Figure 8 1 Indicator Overall Dimensions 3 28 83 5 mm...

Page 36: ...l interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at...

Page 37: ...as been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other tha...

Page 38: ......

Page 39: ......

Page 40: ...haus Corporation 7 Campus Drive Suite 310 Parsippany NJ 07054 USA Tel 1 973 377 9000 Fax 1 973 944 7177 www ohaus com P N 30529806 A 2019 Ohaus Corporation all rights reserved Printed in China 3052980...

Reviews: