1. INTRODUCTION 

This manual contains installation, operation and maintenance instructions for the Navigator

®

 Series. 

Please read the manual completely before using the balance. 

 

1.1 Safety Precautions 

Please follow these safety precautions: 

 

Verify that the AC Adapter input voltage matches the local AC power supply. 

 

Only use the balance in dry locations. 

 

Do not operate the balance in hostile environments.  

 

Do not drop loads on the platform.  

 

Service should be performed only by authorized personnel. 

 

1.2. Controls 

 

Standard (non-approved) models – shown with LED display. 

 

Button Functions 

Zero 

 

 
Yes

 

Short Press (when on):  Sets display to zero 
                    (when off):  Turns balance on 
Long Press (when on):  Turns the balance off 
Short Press (in Menu):  Selects/accepts displayed setting 

Print 
Units 
No 

Short Press:  See Interface Manual for operation description. 
Long Press:  Toggles through active units 
Short Press (in Menu):  Toggles through available settings 

Function 
Mode 
Back 

Short Press:  Selects function setting 
Long Press:  Selects active Mode 
Short Press (in Menu):  returns to previous settings 

Tare 
Menu 
Exit 

Short Press:  Enter / clear a Tare value 
Long Press:  Enters User Menu 
Short Press (in Menu):  Quickly exit User Menu 

IR Sensor-Left 
IR Sensor
-Right 

IR Sensors can be programmed to act as “touchless” buttons. See the 
User Menu section 4.3 for the available settings. 

The IR Sensors can be activated by a hand or other object that is placed about 12mm (½ inch) 
above the sensor locations. The sensor activation distance will vary based on the reflective nature 
of the object. If unwanted activations occur due to unique situations the sensors can be turned off. 

Summary of Contents for Navigator NV1101

Page 1: ...Navigator Balances Instruction Manual 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Page 2: ......

Page 3: ...t Press in Menu Selects accepts displayed setting Print Units No Short Press See Interface Manual for operation description Long Press Toggles through active units Short Press in Menu Toggles through available settings Function Mode Back Short Press Selects function setting Long Press Selects active Mode Short Press in Menu returns to previous settings Tare Menu Exit Short Press Enter clear a Tare...

Page 4: ...nsportation Lock The Transportation Lock is located under the balance Rotate the pointer to the unlocked position Note No shipping lock on Approved models 2 3 Location Use the balance on a firm steady surface Avoid locations with excessive air current vibrations heat sources or rapid temperature changes Adjust the leveling feet so the bubble is centered in the circle ...

Page 5: ...ion manual for step by step instructions as well as disposal instructions Caution Risk of explosion can occur if the rechargeable battery is replaced with the wrong type or if it is not properly connected 2 5 Initial Calibration When the balance is first installed it should be calibrated to ensure accurate results Press and hold Menu until mMeNU Menu is displayed When the button is released the di...

Page 6: ...Yes to calculate the APW The display shows the piece count Note Press Function to view the current APW 6 Add additional pieces until the desired count is reached 7 To clear the stored APW press and hold Mode until Count is displayed Press Yes when Clr APU is displayed 3 3 Percent Mode This mode measures the weight of a sample as a percentage of a reference weight 1 Place an empty container on the ...

Page 7: ... 5 for all of the items to be added Note While the display indicates zero press Function to view the current total number of samples and the total weight 7 To clear the stored total press and hold Mode until ACCUmM is displayed Press Yes when Clr Acc is displayed 3 6 Checkweigh Mode This mode sets low and high weight limits for portion control processes 1 Press and hold Mode until CHeCk Check is d...

Page 8: ... menu 4 2 Cal Sub Menu Span SpaN yes no Initiates a span calibration procedure zero and span A span calibration is important when initially setting up the balance Lin Lin yes no Initiates a linearity calibration procedure zero mid point and span 4 3 Setup Sub Menu The backlit LCD and red LED displays will have different menu items or settings based on the functionality Auto Off A Off on off When A...

Page 9: ...it menus The switch in type approved models may set some balance settings as required by the approval agency The switch may be secured using paper seals wire seals or plastic ties Locked Unlocked 5 MAINTENANCE 5 1 Troubleshooting The following table lists common problems and possible causes and remedies If the problem persists contact OHAUS or your authorized dealer Symptom Possible Cause Remedy C...

Page 10: ...659 between 8 00 AM and 5 00 PM EST An OHAUS product service specialist will be available to provide assistance Outside the USA please visit our web site www ohaus com to locate the OHAUS office nearest you 5 3 Accessories Rechargeable Battery Kit 83032106 NVL NVT RS232 Interface Kit 83032107 NV NVL NVT USB Interface Kit 83032108 NV NVL NVT Ethernet Interface Kit 83032109 NV NVL NVT In Use Cover K...

Page 11: ...L 194 mm x 203 mm NVT 230 mm x 174 mm Net Weight2 NV 0 9 kg 2 2 lb NVL 1 5 kg 3 3 lb NVT 1 5 kg 3 3 lb Shipping Weight2 NV 1 4 kg 3 1 lb NVL 2 3 kg 5 1 lb NVT 2 3 kg 5 1 lb Note 1 Some application modes are restricted in Approved models Note 2 1 and 3 models add 0 5kg 1lb Non Approved Models Model1 Capacity Readability d Repeatability Linearity Span Cal Wt Lin Cal Wts NV212 210g 0 01g 1d 2d 200g 1...

Page 12: ... 0 5g III 1kg 1kg 1 5kg NVT3200 3200g 1g III 2kg 2kg 3kg NVT6400 6400g 2g III 5kg 3kg 6kg NVT16000 16000g 5g III 10kg 10kg 15kg Note 1 M EC Type approved N NTEP and Measurement Canada approved Note 2 1 Factory installed rechargeable battery option 2 LED display 3 LED display with factory installed rechargeable battery option Example NVT3200M 3 6 2 Drawings A B C NV 204 mm 8 in 212 mm 8 4 in 58 mm ...

Page 13: ...dopted European standard EN 45501 1992 paragraph 8 2 2 If national regulations limit the validity period of the verification the user of the weighing instrument must strictly observe the re verification period and inform the respective weights and measures authorities Disposal In conformance with the European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE this device may no...

Page 14: ...was re registered to the ISO 9001 2000 standard Limited Warranty OHAUS products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period During the warranty period OHAUS will repair or at its option replace any component s that proves to be defective at no charge provided that the product is returned freight prepaid to OHAUS T...