CKW-55 CHECKWEIGHER
EN-31
3.6.4 Print Menu
The Print Menu provides settings for printing methods and options.
RESET
This menu item is used to reset the Print menu to factory defaults. Selections are:
No
, Yes.
Print Stable Data Only
This menu item is used to enable or disable the printing of stable values only. Selections are:
OFF,
On (default if LFT is On).
Auto Print
This menu item is used to select automatic printing options.
Selections are:
O F F
O F F
O F F
O F F
O F F
= Auto-print feature is off.
On Stable
= Prints first stable non-zero value after each change in weighing
value.
Interval (INTRVL)
= Prints data on user-selected intervals. This allows specifying the
print interval times (in seconds from 1 to 3600).
Continuous
= Prints data continuously.
Print Content
This menu item is used to define the content of the printed data. Selections are:
Display
= Allows printing of the displayed weight. Selections are: OFF or
On.
Numerical
= Allows output of numeric data only, no additional descriptive text will
be printed. Selections are:
OFF
, On.
Header
= Allows printing the pre-set header (OHAUS, Model No., and software
version). Selections are:
OFF
= Header data is not printed.
Single
= Header data is printed only once at the very next printout*.
Cont
= Header data is printed in each printout of weighing result.
Setpoint Data
= Allows printing of the Setpoint Input values. Selections are:
OFF
= Setpoint Input data is not printed.
Single
= Setpoint Input data is printed once only at the very next printout*.
Cont
= Setpoint Input data is printed in each printout of weighing result.
*
Note
: The Single printout option is reset at each power on cycle, or if the
single setting is reselected.