background image

 

BW SERIES COMPACT BENCH SCALE EN-11

7. CLEANING AND MAINTENANCE

      

Comply wth safety precautons when cleanng and mantanng the scale

 

•  Turn off and dsconnect the scale from the power supply durng cleanng.

 

• 

DO NOT

 open the scale; no user reparable components nsde.  Servce   

 

 

should be performed by authorzed personnel only.

 

• 

DO NOT

 place the scale upsde down.  If accessng the bottom, place the  

 

 

scale on ts sde.

 

• 

DO NOT

 carry the scale by the pan or sub-platform.  Use the handholds on  

 

 

the sdes of the scale housng.

 

• 

DO NOT

 allow lquds to enter the scale.

 

• 

DO NOT 

use hgh pressure when cleanng the scale.

 

•  Inspect the scale regularly.  Ensure that the housng, pan and sub-platform  

 

 

are clean and free from foregn materal. 

 

•  Wpe the exteror components of the scale usng a soft cloth dampened wth  

 

 

water and a mld detergent (

DO NOT

 use acds, alkals, strong solvents or  

 

 

abrasve cleanng agents).

 

•  Screw n all 4 levelng feet tghtly to avod entry of water nsde the scale      

 

  

durng cleanng.  However, when the scale s put back nto operaton, 

 

 

remember to loosen the two rear feet (and adjust levelng accordngly) to  

 

 

allow proper ar flow and mnmze condensaton nsde the scale.

 

•  Plug the rubber cap to the adapter receptacle underneath the scale to avod  

 

 

entry of water nsde the scale.

 

•  The pan s dshwasher safe and may be placed wth normal loads.  All other  

 

 

parts must not be placed n a dshwasher.

Summary of Contents for BW1.5

Page 1: ...BW Series Compact Bench Scale B scula compacta de mesa de la Serie BW Balance de table compacte s rie BW Kompakte Tischwaage der BW Serie Bilancia da banco Compact serie BW...

Page 2: ...ii...

Page 3: ...nung Bassa tensione 89 336 EEC EN61326 1 A1 1998 A2 2001 Electromagnetic compatibility Compatibilidad electromagn tica Compatibilite lectromagnetique Elektromagnetische Vertr glichkeit Compatibilit el...

Page 4: ...apa de la verificaci n inicial debe ser llevada a cabo por la organizaci n de servicio aprobada del represent ante autorizado dentro de la CE o por las autoridades nacionales de pesos y medidas La pri...

Page 5: ...sprechenden Beh rden f r Ma e und Gewichte informieren Gli strumenti di pesa certificati sul luogo di fabbricazione recano sull etichetta della confezione uno dei marchi mostrati qui accanto e l adesi...

Page 6: ...disponga de este producto de acuerdo con las normas locales en el punto de recolecci n especificado para equipos el ctricos y electr nicos Si tiene alguna pregunta s rvase consultar a la autoridad re...

Page 7: ...lls bermittelt werden Vielen Dank f r Ihren Betrag zum Umweltschutz In base alla direttiva europea WEEE 2002 96 CE sui rifiuti di apparecchiature elettriche ed elettroniche Waste Electrical and Electr...

Page 8: ...ion d enregistrement ISO 9001 Ohaus Corporation tats Unis d Am rique confir mant que le syst me de gestion de la qualit Ohaus tait conforme aux condi tions normalis es de l ISO 9001 Le 15 mai 2003 Oha...

Page 9: ...2 Battery Power EN 4 2 6 Initial Calibration EN 4 3 OVERVIEW OF CONTROLS AND FUNCTIONS EN 5 4 OPERATIONS EN 6 4 1 Switching the Unit On and Off EN 6 4 2 Manual Tare EN 6 4 3 Zero Operation EN 6 4 4 Ch...

Page 10: ...P65 dust and water jet protection 4 adjustable leveling feet with integrated front panel leveling indicator Bright red LED weight display 6 digit 7 segment 14 mm high characters 4 button control panel...

Page 11: ...to ensure proper transport protection 2 3 Selecting the Location Operate the scale on a firm level surface Avoid locations with rapid temperature changes excessive air currents vibrations electromagn...

Page 12: ...by the illuminated LED over the indi cator NOTES To maximize battery power the scale can be set up to enter Sleep mode only decimal points are displayed after 2 minutes of inactivity or auto matically...

Page 13: ...xits to Save In CHECK Mode ends Over Under setup and exits to weighing mode Initiates CHECK Over Under setup In SETUP Mode Back reverts to the previous parameter In CHECK Mode shifts to the next digit...

Page 14: ...ompares the weight of an item against a pre set Over Under range To activate Checkweighing Mode refer to user setup Section 5 2 Press CHECK to initiate entering Over Under parameters The value of the...

Page 15: ...minutes of inactivity ON enables this function OFF disables this function S2 Scale enters sleep mode after 2 minutes of inactivity ON enables this function OFF disables this function S3 CHECK activat...

Page 16: ...at the bottom of the scale then short the calibration pins a small slotted screwdriver may be used Note When accessing the bottom of the scale avoid placing the scale upside down on the pan or sub pla...

Page 17: ...lue Place the indicated calibration weight on the center of the pan With the scale stable press ON OFF Yes The display will count down from 5 to 1 as the scale registers the calibration weight 10 xxxx...

Page 18: ...scale may be sealed in the following manner Lead and Wire Seal Secure sealing plate with through hole screws Run the wire seal into the through holes then press the lead seal in place Sticker Seal Sec...

Page 19: ...scale Inspect the scale regularly Ensure that the housing pan and sub platform are clean and free from foreign material Wipe the exterior components of the scale using a soft cloth dampened with water...

Page 20: ...sub platform are unobstructed Scale does not display accurately Improper calibration Calibrate the scale using proper calibration weights nnnnnn displayed Overload condition Load on the pan exceeds sc...

Page 21: ...BW SERIES COMPACT BENCH SCALE EN 13 9 TECHNICAL DATA 9 1 Drawings 230 mm 180 mm 230 mm 127 mm 310 mm...

Page 22: ...tile mechanical keys ON OFF CHECK TARE ZERO Calibration Weight 2 3 and Full Scale Capacity Over Range Capacity Full Scale Capacity 9d Tare Range Full Capacity by Subtraction Zero Range Power on 10 Key...

Page 23: ...ct has been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other...

Page 24: ...rededor del mundo Avec des bureaux dans le monde entier Weltweite Gesh ftsstellen Con uffici in tutto il mondo www ohaus com P N 80251077 A Ohaus Corporation 2006 all rights reserved todos los derecho...

Reviews: