background image

INSTRUCTION MANUAL

4

REMARKS

•  The FG1 generator requires very little water pressure to work properly. If you do not have 

a minimum water pressure you can use a water pump.

•  It is recommended to clean the inside circuit of the machine after each use. To do this, you 

must remove the foam absorber tube with fi lter (12) from the container with foam liquid 

and open (“ON”) the inlet water tap (10) for a few seconds

•  If you work directly connected to the water network, always make sure that the jerrycan 

with foam liquid is always below the level of the foam fl uid connection (11) of the FG1 

generator.

•  The suction power of the foam generator is related to the water pressure. Thus, this will 

aff ect the maximum height with what you will be able to work. In case you have low water 

pressure and consequently the machine is not able to suck the foam liquid you will need 

to elevate the jerrycan of foam fl uid or either use a pump. 

3/B  –  Pumping  PREMIX.  Working  with  PREMIX  means  having  the  foam  fl uid  already 

diluted and mixed in a tank from which the mixture is directly pumped to the foam generator. 

3/B-1. Fill your tank with water and add the foam FLUID at the rate indicated on the 

bottle of your foam fl uid. Our foam fl uids are very concentrated and the suggested 

dose is between 1 to 2% depending on the foam liquid acquired.

When working with PREMIX, it is then not necessary to use the absorption tube for 

foam fl uid (12) provided. Thus, you must close the foam fl uid tap (13).

3/B-2. Connect the hose coming from the pump output, to the Inlet water connection (9) 

on the machine. Now you can proceed with point 4 of ASSEMBLY AND OPERATION

4.  Electrical connection: Place the power supply (1) away from the FG1 machine where it 

is protected from water and can not get wet. Connect the power supply (1) to the power 

source  via  power  input  socket  (2).  Make  sure  that  the  socket  has  earth.  Connect  the 

power cable FG1 (7) to the low voltage output socket (5) of the power supply. Keep the 

power supply switch (3) turned off  (position 0).

5.  Start-up: Start the generator by turning on the power supply (3) (position I). Then open 

the water tap (10) and start the pump of the tank in case you work with tank and pump. 

The generator FG1 will draw some water and immediately after that it will start to produce 

foam.

6.  Shutdown and Disassembly: Close the general key of your water supply or turn off  the 

pump of the tank if you work with tank and pump. Then turn off  the power supply (switch 

(3) to position “0”). Then proceed to disconnect the machine.

Summary of Contents for FG-1

Page 1: ...INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES FG 1 FOAM GENERATOR...

Page 2: ...generator FG1 7 Power cable FG1 8 Anchoring holes with clamp 9 Water connection WATER 10 Water tap 11 Foaming liquid connection FLUID 12 Foam absorber tube with lter 13 Fluid tap 14 Locking knobs 15...

Page 3: ...gh it is better to leave it completely open Since the machine mixes the uid with the incoming water it is better to regulate the out ow of the machine with the Inlet Water tap and thus not to deregula...

Page 4: ...he rate indicated on the bottle of your foam uid Our foam uids are very concentrated and the suggested dose is between 1 to 2 depending on the foam liquid acquired When working with PREMIX it is then...

Page 5: ...use and duly certi ed Do not cover the audience with foam The maximum foam level should allow you to maintain eye contact with the audience Do not wet or cover the power supply To clean it use a damp...

Page 6: ...e espuma FG1 7 Cable de alimentaci n FG1 8 Ori cios de anclaje con abrazadera 9 Toma de agua WATER 10 Llave de paso de agua 11 Toma de l quido espum geno FLUID 12 Tubo de absorci n de l quido espum ge...

Page 7: ...t doblado obstruyendo el paso de l quido 3 Trabajando con dep sito con premix y bomba 3 1 Conecte la manguera no incluida provinente de la bomba del dep sito a la toma de agua 9 del generador FG1 Aseg...

Page 8: ...G1 precisa de muy poca presi n de agua para funcionar correctamente Si no dispone de una m nima presi n de agua puede utilitzar una bomba de agua Es recomendable limpiar el circuito interior de la m q...

Page 9: ...www ohfx eu...