background image

INSTRUCTION MANUAL

3

1.  Placement: Place the foam generator FG1 (6) on a fl at and stable surface, on a tripod by 

means of the tripod accommodation (15) or hang on a structure by means of two clamps 

in the anchoring holes (8). Secure the machine with a safety cable suitable for the weight 

of the machine. Adjust the inclination of the generator and tighten the locking knobs (14) to 

fi x the inclination. If you use a tripod, make sure it is completely stable and supports 30 kg.

If you are going to use the generator connected to the water network, follow the instructions 

in point 2 of assembly and operation. If you are going to use a water tank + pump, follow 

the instructions of assembly and operative point 3

2.  Working with water network.

2.1- Water connection: Connect the water hose (not included) to the water inlet connection 

(9) of the FG1 generator. Make sure that the inlet water tap (10) is turned ON and keep the 

general tap of your water supply closed.

2.2-Foaming fl uid inlet: Insert the fi lter at one end of the foam absorber tube (12) into a 

container with foam liquid ready for use. Check that the foaming liquid connection (11) is 

fully open (“ON” position) and that the tube is not bent, obstructing the passage of liquid.

This small tap is to regulate the entry of foam fl uid, although it is better to leave it completely 

open. Since the machine mixes the fl uid with the incoming water, it is better to regulate the 

outfl ow of the machine with the Inlet Water tap and thus not to deregulate the proportion 

of foam fl uid and water

3.  Working with deposit and pump.

As previously described, you may fi nd that where you plan to use the foam generator, you 

do not have either enough water pressure (< 1,5 BAR) or if there is pressure, the water 

fl ow is weak. In these cases, it is recommended to work with a water pump. 

You then can choose if to pump only the water to the foam generator, or pump a PREMIX 

(the mixure of water + foam fl uid) 

3/A – Pumping water 

3/A-1- Fill your tank with water. 

3/A-2 Submerge the pump into the tank. It should be in horizontal position so that the 

pump is always well refrigerated. The pump cannot run out of water. (Risk of burning). 

3/A-3- Connect the hose coming from the pump, to the inlet water tap of the machine. 

Insert the fi lter into a container with foam liquid ready for use. Check that the foam 

fl uid tap (13) is fully open (“ON” position) and that the tube is not bent, obstructing the 

passage of liquid.

3/A-4- Now you can proceed with point 4 of ASSEMBLY AND OPERATION.

During  the  use  of  the  machine,  you  may  wish  to  let  a  water  hose  fi lling  the  tank 

(especially if your tank is not too big). In this way, in the meantime the machine is 

consuming water, you get more water inside the tank and thus it takes longer to empty 

the tank. 

ASSEMBLY AND OPERATION

Summary of Contents for FG-1

Page 1: ...INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES FG 1 FOAM GENERATOR...

Page 2: ...generator FG1 7 Power cable FG1 8 Anchoring holes with clamp 9 Water connection WATER 10 Water tap 11 Foaming liquid connection FLUID 12 Foam absorber tube with lter 13 Fluid tap 14 Locking knobs 15...

Page 3: ...gh it is better to leave it completely open Since the machine mixes the uid with the incoming water it is better to regulate the out ow of the machine with the Inlet Water tap and thus not to deregula...

Page 4: ...he rate indicated on the bottle of your foam uid Our foam uids are very concentrated and the suggested dose is between 1 to 2 depending on the foam liquid acquired When working with PREMIX it is then...

Page 5: ...use and duly certi ed Do not cover the audience with foam The maximum foam level should allow you to maintain eye contact with the audience Do not wet or cover the power supply To clean it use a damp...

Page 6: ...e espuma FG1 7 Cable de alimentaci n FG1 8 Ori cios de anclaje con abrazadera 9 Toma de agua WATER 10 Llave de paso de agua 11 Toma de l quido espum geno FLUID 12 Tubo de absorci n de l quido espum ge...

Page 7: ...t doblado obstruyendo el paso de l quido 3 Trabajando con dep sito con premix y bomba 3 1 Conecte la manguera no incluida provinente de la bomba del dep sito a la toma de agua 9 del generador FG1 Aseg...

Page 8: ...G1 precisa de muy poca presi n de agua para funcionar correctamente Si no dispone de una m nima presi n de agua puede utilitzar una bomba de agua Es recomendable limpiar el circuito interior de la m q...

Page 9: ...www ohfx eu...