background image

INSTRUCTION MANUAL

4

REMARKS

• The FC1 cannon require very little water pressure to function properly. If you do not have

a minimum water pressure you can use a water pump.

It is recommended to clean the inside circuit of the machine after each use. To do this, you

must remove the foam absorber tube with fi lter (12) from the container with foam liquid

and open (“ON”) the inlet water tap (10) for a few seconds.

If you work directly connected to the water network, always make sure that the jerrycan

with foam liquid is always below the level of the foam fl uid connection (11) of the FC1

cannon.

3/A-4- Now you can proceed with point 4 of ASSEMBLY AND OPERATION.

During  the  use  of  the  machine,  you  may  wish  to  let  a  water  hose  fi lling  the  tank 

(especially if your tank is not too big). In this way, in the meantime the machine is 

consuming water, you get more water inside the tank and thus it takes longer to 

empty the tank. 

3/B –  Pumping PREMIX. Working with PREMIX means having the foam fl uid already 

diluted and mixed in a tank from which the mixture is directly pumped to the foam cannon. 

3/B-1. Fill your tank with water and add the foam FLUID at the rate indicated on the 

bottle of your foam fl uid. Our foam fl uids are very concentrated and the suggested 

dose is between 1 to 2% depending on the foam liquid acquired.

When working with PREMIX, it is then not necessary to use the absorption tube for 

foam fl uid (12) provided. Thus, you must close the foam fl uid tap (13).

3/B-2. Connect the hose coming from the pump output, to the Inlet water connection (9) 

on the machine. Now you can proceed with point 4 of ASSEMBLY AND OPERATION.

4.

Electrical connection: The FC1 machine runs at low voltage (30v) and is waterproof.

 

However, it’s power supply/transformer is not waterproof and thus must be away from

 

water.  This  is  why  the  machine  is  equipped  with  a  long  cable.  Place  the  power 

supply

(1)

away from the FC1 machine where it is protected from water and cannot get wet.

 

Connect the power supply (1) to the power source via the power input socket (2). 

Make

 

sure that the socket has earth. Turn ON the power switch (3) and check that 

the power

 

LED indicator (4) is on. Connect the FC1 power cable (7) to the low voltage 

outlet (5) of

 

the power supply.

5.

Start-up: Start the cannon by 

rotating

 

clockwise 

the switch (8) to ON position.

 

 Then open 

the

 

inlet water tap (10). The cannon will draw some water and immediately after that it 

will

 

start to produce foam. You can slightly regulate the distance of the foam jet by 

opening

 

more or less the water inlet tap.

6.

Shutdown and Disassembly: Close the inlet water tap (10) and then turn OFF the rotative

 

switch (8). Then proceed to disconnect the machine from the power supply.

Summary of Contents for FC-1 FOAM

Page 1: ...INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES FC 1 FOAM CANNON...

Page 2: ......

Page 3: ...1 7 Power cable 8 ON OFF switch for FC1 9 Water connection WATER 10 Inlet Water tap 11 Foam uid connection FOAM 12 Absorption tube for foam uid 13 Fluid tap 14 Locking knob 15 Accommodation for tripod...

Page 4: ...er into a container with foam liquid ready for use Check that the foam uid connection 11 is fully open ON position and that the tube is not bent obstructing the passage of liquid This small tap is to...

Page 5: ...sted dose is between 1 to 2 depending on the foam liquid acquired When working with PREMIX it is then not necessary to use the absorption tube for foam uid 12 provided Thus you must close the foam uid...

Page 6: ...his use and duly certi ed Do not cover the audience with foam The maximum foam level should allow you to maintain eye contact with the audience Do not wet or cover the power supply To clean it use a d...

Page 7: ......

Page 8: ...le de alimentaci n FC1 8 Interruptor ON OFF FC1 9 Toma de agua WATER 10 Llave de paso de agua 11 Toma de l quido espum geno FLUID 12 Tubo de absorci n de l quido espum geno con ltro 13 Llave de paso d...

Page 9: ...do el paso de l quido 3 Trabajando con dep sito con premix y bomba 3 1 Conecte la manguera no incluida provinente de la bomba del dep sito a la toma de agua 9 del ca n FC1 Aseg rese que la llave de pa...

Page 10: ...n accesorio y contacte con su distribuidor Cualquier manipulaci n no autorizada invalidar la garant a Solo una persona adulta y cuali cada debe manipular la m quina OBSERVACIONES El ca n FC1 precisa...

Page 11: ......

Page 12: ...www ohfx eu...

Reviews: