When  you  purchase  a  TotalArc  Relighter  you  purchase  a  product  of  “Quality,  integrity,  and  innovation  from  concept  to 
commissioning.”  Please  read  through  the  entire  manual  to  get  familiar  with  installation  and  operations  of  the  TotalArc 
Relighter.  
 
The TotalArc Relighter is a flame monitoring device that monitors flame status and reacts to a flame failure by creating a 
spark. The TotalArc system will close the main gas valve supply to the burner to minimize the amount of gas entering the 
fire tube while a relight is in process.  
 
The operation stage of the TotalArc is indicated by a green light installed on the front of the control enclosure. See operation 
instructions for light code indication status descriptions.  
 
The  TotalArc  System  can  be  purchased  to  operate  with  three  different  power  sources.  Confirm  power  availability  at 
installation site and select one of the following models:  
   
   

 

OGI Part# 460246 / 450592 (Polycarbonate / Stainless Steel) 

   

 

Solar Powered System 

This system is provided with a solar panel and all required installation hardware. The solar panel provided 
is sized to 35 Watts, but solar systems can be supplied  with a solar panel  up to 50 Watts (subject to 
availability). The method of energy storage system is a 12 VDC sealed lead battery.  
 
OGI Part# 460312 / 450490 (Polycarbonate / Stainless Steel)  

120 VAC Powered System  

This model connects to a 120 VAC power source. This model also contains an internal battery back up 
system designed to maintain stable and uninterrupted power supply to the TotalArc control system. The 
battery back up provided with this system is intendeded to maintain power during short time periods or 
power fluctuations periods. 
 
OGI Part# 460371 / 450591 (Polycarbonate / Stainless Steel) 

12-24 VDC Powered System

  

This model connects to a 12-24 VDC power source, no battery back up is included on this model. This 
system typically connects to an RTU power source that will typically have a built-in power back up. 
 
**The TotalArc Relighter is a fully customizable productline – other options are available upon request. 
Please speak to an OGI Sales Representative to discuss options to fit your needs** 
 

     

 

* * *

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INTRODUCTION 

 

Summary of Contents for TotalArc BMS 460246 SOLAR POWER

Page 1: ...ct of Quality integrity and innovation from concept to commissioning That promise along with proper maintenance will ensure that your TotalArc Relighter gives you years of rugged trouble free performa...

Page 2: ...or s manual Figure 1 1 ON OFF POWER SWITCH 2 STATUS INDICATOR LIGHT 3 IGNITION PUSH BUTTON 4 MAIN GAS SHUTOFF SOLENOID 5 TOTALARC ENCLOSURE 6 CUSTOMER POWER ENTRY 7 M12 RECEPTACLE 8 IGNITION MODULE CA...

Page 3: ...II FIGURE 2 IGNITION MODULE Installation in Flame Arrestor For details see Installation instructions on page 7...

Page 4: ...INSTALLATION TotalArc kit includes mounting feet for easy installation For details see Installation instructions on page 6 FIGURE 3B INSTALLATION MOUNTING PATTERN FOR TOTALARC ENCLOSURE SEE FIGURE 3B...

Page 5: ...IV FIGURE 4 Clamshell Installation FIGURE 5 Battery Connection Detail SOLAR OPTION ONLY...

Page 6: ...V FIGURE 6 Ignition Rod Installation Figure 7 BASO Pilot Safety Valve...

Page 7: ...VI Figure 8 Solar Panel Assembly...

Page 8: ...VII Figure 9 Solar Panel Assembly...

Page 9: ...mportant Safety Instructions 2 Symbols 3 4 Electrical 4 Features 5 Assembly 5 7 Operation 8 9 Maintenance 10 Trouble Shooting 11 12 Wiring Diagrams 13 14 Warranty 15 Parts Ordering and Service Back Pa...

Page 10: ...s system is provided with a solar panel and all required installation hardware The solar panel provided is sized to 35 Watts but solar systems can be supplied with a solar panel up to 50 Watts subject...

Page 11: ...ntrol cable periodically and if damaged have it replaced by an authorized service facility Make sure all control cable clam shell guards are properly and securely attached prior to power up stage Use...

Page 12: ...used on this product Please study them and learn their meaning Proper inter pretation of these symbols will allow you to operate the product better and safer SYMBOL NAME DESIGNATION EXPLANATION Safet...

Page 13: ...t 25 C OGI PART 460312 VAC Powered Control Panel Nominal System Voltage 85 264 VAC Rated Current Input 1 35A at 120 VAC 0 65A at 230 VAC OGI PART 460371 VDC Powered Control Panel Nominal System Voltag...

Page 14: ...ring shipping Carefully remove the product and any accessories from the box Make sure that all items listed in the packing list are included Donotdiscardthepackingmaterialuntilyouhavecarefully inspect...

Page 15: ...all clam shell around the connectors See Figure 4 pg IV These shells are required to maintain Class 1 Division 2 rating Failure to apply clam shells could lead to a hazardous work environment Do NOT c...

Page 16: ...tion is set tighten the set screw Ground connection remove one side of the metal clamp holding the ceramic insulator and install provided 12AWG THHN green ground wire with terminal connector and repla...

Page 17: ...matic control pressure to flow to the remainder of the burner specific safeties If the pilot flame is lost and not relit the BASO will trip isolating and shutting down the burner pilot and venting off...

Page 18: ...9 TYPICAL HEATER WITH TOTALARC RELIGHTER P ID ARRANGEMENT...

Page 19: ...und connection at pilot assembly e Visually check the Control Panel and instrumentation for moisture condensation connections etc f In Northern locations where snow accumulation could be a problem cle...

Page 20: ...h burner TCV RELEASED the system has maintained the main gas closed for a period of two minutes and has now been released TotalArc main gas valve released to OPEN BASO Pilot Guard should cool down and...

Page 21: ...s power source can not be disconnected since it comes directly from solar panel Follow proper procedures while performing this test If no areas of concern are found please call OGI Service Department...

Page 22: ...SCHEMATICS 13 SOLAR POWER TOTALARC P N 460246 120VAC POWER TOTALARC P N 460312 12 24VDC POWER TOTALARC P N 460371...

Page 23: ...14 Enclosure Connections for all systems Trouble and Gas Shut Off Relay Connections for all systems TOTALARC TROUBLE RELAY DRY CONTACT SET CLOSED TROUBLE OPEN OKAY...

Page 24: ...nufacturer s warranty and Seller must authorize return of such material prior to its return shipment Buyer shall bear the expense of packing and shipping proposed defective parts and components and th...

Reviews: