HEART RATE(HR) NOT FUNCTIONING/
ERRATIC READING
A
HAND PLUSE
NOT FUNCTIONING
C
BOTH HEART RATE
NOT FUNCTIONING
B
WIRELESS CHEST BELT
NOT FUNCTIONING
CHECK HAND PLUSE
CONNECTOR
IN HAND ARM BOTH SIDE
CHECK CABLE FROM
HAND PLUSE SENSOR
TO COMPUTER
IS CHEST BELT
BATTRY LOW ?
DOES HR RECEIVER
PICK UP
HR SIMULATOR ?
DOES RECEIVER FROM
3PIN TEST PIN1 GND AND
PIN2 SIGNAL ?
IS LOOSE CONNECTION ON
HEART RATE RECEIVER ?
IS LOOSE CONNECTION
ON HEART RATE PC BOARD ?
RECONNECT
BAD
GOOD
0 OHM
CHECK CABLE AND
RECONNECT
OL OHMS
REPLACE BATTRY
REPLACE CHEST STRAP
YES
YES
NO
HIGH LOW OUT
DC VOLTAGE
REPLACE RECEIVER
NO
NO
RECONNECT
RECONNECT
BAD
GOOD
BAD
GOOD
REPLACE COMPUTER
LIFT RECEIVER AWAY
FROM PANEL
NO HR
CHECK FOR SOURCES
OF INTERFERENCE
HR GOOD
YES
YES
YES
NO
NO