Ofs 432 Installation Manual Download Page 14

Issue2 

November 14, 2011 

 

- 13 - 

 

 
Pad Installation Procedures 

 
Have the following equipment ready before beginning this procedure: 
 

1.

 

One masonry drill 

2.

 

One 5/8” (15.9 mm) masonry drill bit 

3.

 

Masonry expansion anchors 

4.

 

One 9/16” wrench 

5.

 

A pencil 

6.

 

One Hammer 

 

Use the procedure below to mount the cabinet on an existing concrete slab.   
 

1.

 

Position the provided template on the slab in the desired location for the 
cabinet and mark the location of the mounting holes with respect to the cable 
entry area. 

 
2.

 

Place the template out of the way. 

 

3.

 

Drill 5/8” (15.9 mm) diameter by 3” (7.62 cm) deep holes at the locations 
marked in step 2. 

 
4.

 

Insert anchor bolts into the holes in the slab and tap them firmly into the holes 
with a hammer. 

 
5.

 

Remove the nuts and washers from the expansion anchors. 

 
6.

 

Remove the rear panels and seals from the cable entry area of the cabinet. 

 

7.

 

Remove the mounting bolt access covers from the plinth. 

 
8.

 

Place the cabinet over the studs and reinstall nuts and washers.  Secure the 
cabinet to the slab by securely tightening all anchor bolts to 40 ft-lbs or as 
recommended by the expansion anchor manufacturer. 

 

9.

 

Reinstall the mounting bolt access covers on the plinth. 

 
10.

 

Remove portion of the cable entry seals corresponding to the diameters of the 
cables. Install the split cable seals around the cables and slide them down the 
cables to the base of the cabinet. 

 

11.

 

 Reinstall the cable entry panels. 

 

 

 

Summary of Contents for 432

Page 1: ...Issue2 November 14 2011 0 432 Outdoor Fiber Distribution Cabinets Installation Manual...

Page 2: ...North America Inc DISCLAIMER OF LIABILITY The contents of this document as of the date of publication are current OFS reserves the right to change the contents without prior notice OFS in no way will...

Page 3: ...ut this Manual 3 Product Overview 3 Product Specifications 5 Warnings 6 Inspecting Shipment 6 Replacement and Accessory Kits 6 Installation 7 Pole Mounting 7 Pad Installation 10 Grounding 14 Fiber Rou...

Page 4: ...pole mountable outdoor The 432 FDC cabinet has overall dimensions of 36 inches in height 18 inches in depth and 24 inches in width Figure 4 Figure 1 432 Outdoor Fiber Distribution Cabinet A 432 Fiber...

Page 5: ...ated in the bottom rear section of the equipment bay Removable panels are provided at the base of the cabinet which allow the cabinet to be slid over the input and output cables without threading the...

Page 6: ...Issue2 November 14 2011 5 Product Specifications 432 Fiber Distribution Cabinet Figure 4 Rear view of cabinet showing rear panel...

Page 7: ...note any signs of damage 2 Unpack the containers and carefully inspect the contents for damage 3 If the equipment has been damaged in transit immediately report the extent of the damage to the transpo...

Page 8: ...anel 1 Seal cabinet door Foam tape 1 8 x Roll Seal 2 port cable entry 3 Door Latch Installation Manual 1 Table 1 Replacement and Accessory Kit Contents Installation Instructions 432 Outdoor Fiber Dist...

Page 9: ...Issue2 November 14 2011 8 Table 2 Pole Mounting Kit Bill of Materials Figure 7 Dimensions for Pole Mounting...

Page 10: ...ure 6 4 Insert machine bolt item 30 through mounting bracket and into the mounting hole and press bolt and bracket flush against the pole 5 Place round cupped washer item 33 with the concave side in o...

Page 11: ...item 12 on the upper pole mount bracket 12 If the cable stubs connect to an underground cable dress the cable down the pole If the cable stubs connect to an aerial cable form a drip loop in the cable...

Page 12: ...from the top view Figure 10 Cabinet Footprint The 432 Fiber Distribution Cabinet does not require the threading of input and output cables through the base of the cabinet The cable entry area can be f...

Page 13: ...Issue2 November 14 2011 12 Figure 11 Cable Entry Area Rear View Figure 12 Top View of Cable Entry Area...

Page 14: ...rked in step 2 4 Insert anchor bolts into the holes in the slab and tap them firmly into the holes with a hammer 5 Remove the nuts and washers from the expansion anchors 6 Remove the rear panels and s...

Page 15: ...e following guidelines should be used to ground the cabinet unless local practices rules or regulations dictate otherwise Each door and equipment rack is grounded to the cabinet frame The cabinet fram...

Page 16: ...near the cabinet location 2 Use a Megger type Ohmeter to measure the resistance between the cabinet ground and the ground rods The resistance must be 25 ohms or less 3 If the ohm requirement in step...

Page 17: ...ion Cabinet Fiber routing When routing the pigtails optimize the cable slack by choosing appropriate bend control guides Avoid cable kinking and pulling during the installation Use the shelves and the...

Page 18: ...ndustries 3048 PC Undercover Vault for 432 Fiber Distribution Cabinet 1160 Nicole Court Glendora CA 91760 909 592 6272 Customer Information and Assistance Ordering Entry Customer Service 1 888 342 374...

Reviews: