12
General Faults Judgment
The faults description
Judgment
Machine can't start
1
、
Check whether the electricity protector is cut the
power off, Please press the big bottom on the electricity
protector for reset;
Can't self priming or the pump
pressure is lower than 40Bar
(4Mpa)
1
、
Some air is inside of the pump, need to take out the
outlet pipe and let the machine working for few seconds,
or even use faucet to push the air out of the pump
3
、
The water filter or the inlet pipe fitting is blocked;
3
、
The water and inlet pipe height different is over 0.5
meter;
4
、
The seal of the pump has problem and need to change
the seal parts;
Misting system don't have mist
1
、
The pressure is too low, need to adjust the pressure
valve or reduce the nozzles quantity;
2
、
Some connectors are leaking (Solution: check the
leaking place, change the parts or repair);
3
、
The water filter is blocked and need to be cleaned;
4
、
The seal of the pump is bad and need to change;
5
、
The spring of one-way valve is fatigability
breakage and need to change a new one;
Some of the nozzles can't spray
the mist
The nozzles is blocked and need to clean or change a
new one
The APP is not working correctly
1
、
Please close the APP completely and open it again
;
2
、
Please check whether the mobile or the mobile system
is too old;
The noise is loud and the
machine
is
shaking
when
working or vibrate heavily
1
、
Put the outlet pipe and push the air out of the pump;
2
、
The pump has some problem and need repair;
The pump or motor temperature
is very high
1
、
The pump oil is not enough or not suitable;
2
、
The motor is over work, please reduce the pressure;
The pump and connectors has oil
leakage
1
、
Change the oil seal;
2
、
The nuts is not tight enough;