background image

OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com

7

Warranty and 

Return Policy

Warranty:

OFI Testing Equipment, Inc. (OFITE) warrants that the products shall be free from liens and defects in 

title, and shall conform in all respects to the terms of the sales order and the specifications applicable 

to the products. All products shall be furnished subject to OFITE’s standard manufacturing variations 

and practices. Unless the warranty period is otherwise extended in writing, the following warranty shall 

apply: if, at any time prior to twelve (12) months from the date of invoice, the products, or any part 

thereof, do not conform to these warranties or to the specifications applicable thereto, and OFITE is 

so notified in writing upon discovery, OFITE shall promptly repair or replace the defective products.  

Notwithstanding the foregoing, OFITE’s warranty obligations shall not extend to any use by the buyer 

of the products in conditions more severe than OFITE’s recommendations, nor to any defects which 

were visually observable by the buyer but which are not promptly brought to OFITE’s attention.

In the event that the buyer has purchased installation and commissioning services on 

applicable products, the above warranty shall extend for an additional period of twelve 

(12) months from the date of the original warranty expiration for such products.

In the event that OFITE is requested to provide customized research and development for the buyer, 

OFITE shall use its best efforts but makes no guarantees to the buyer that any products will be provided.

OFITE makes no other warranties or guarantees to the buyer, either express or implied, 

and the warranties provided in this clause shall be exclusive of any other warranties 

including ANY IMPLIED OR STATUTORY WARRANTIES OF FITNESS FOR PURPOSE, 

MERCHANTABILITY, AND OTHER STATUTORY REMEDIES WHICH ARE WAIVED.

This limited warranty does not cover any losses or damages that occur as a result of:

• 

Improper installation or maintenance of the products

• 

Misuse

• 

Neglect

• 

Adjustment by non-authorized sources

• 

Improper environment

• 

Excessive or inadequate heating or air conditioning or electrical 

power failures, surges, or other irregularities

• 

Equipment, products, or material not manufactured by OFITE

• 

Firmware or hardware that have been modified or altered by a third party

• 

Consumable parts (bearings, accessories, etc.)

Returns and Repairs:

Items being returned must be carefully packaged to prevent damage in 

shipment and insured against possible damage or loss. OFITE will not be 

responsible for equipment damaged due to insufficient packaging.

Any non-defective items returned to OFITE within ninety (90) days of invoice are subject to a 

15% restocking fee. Items returned must be received by OFITE in original condition for it to 

be accepted. Reagents and special order items will not be accepted for return or refund.

OFITE employs experienced personnel to service and repair equipment manufactured by us, as 

well as other companies. To help expedite the repair process, please include a repair form with all 

equipment sent to OFITE for repair. Be sure to include your name, company name, phone number, 

email address, detailed description of work to be done, purchase order number, and a shipping address 

for returning the equipment. All repairs performed as “repair as needed” are subject to the ninety (90) 

day limited warranty. All “Certified Repairs” are subject to the twelve (12) month limited warranty.

Returns and potential warranty repairs require a Return Material Authorization (RMA) 

number. An RMA form is available from your sales or service representative.

Please ship all equipment (with the RMA number for returns or warranty repairs) to the following address:

OFI Testing Equipment, Inc.  

Attn: Repair Department  

11302 Steeplecrest Dr.  

Houston, TX 77065

 

USA

OFITE also offers competitive service contracts for repairing and/or maintaining your lab 

equipment, including equipment from other manufacturers. For more information about 

our technical support and repair services, please contact 

[email protected]

.

Summary of Contents for 131-50

Page 1: ...lity Meter Part No 131 50 Instruction Manual Updated 12 10 2015 Ver 3 0 OFI Testing Equipment Inc 11302 Steeplecrest Dr Houston Texas 77065 U S A Tele 832 320 7300 Fax 713 880 9886 www ofite com Copyr...

Page 2: ...rest Dr Houston TX 77065 USA Tel 832 320 7300 Fax 713 880 9886 www ofite com 1 Intro 2 Description 2 Components 3 Specifications 4 Procedure 5 Calibration Performance Test 6 Warranty and Return Policy...

Page 3: ...age is the point at which the drilling fluid be comes electrically conductive The DC power source of the batteries pro vides an AC voltage to the electrodes at a low frequency The unit provides a cons...

Page 4: ...tion Standard 147 02 9 Volt Alkaline Battery Optional 110 10 Marsh Funnel Viscometer or 12 mesh screen 130 38 Thermocup 115 Volt 130 38 1 Thermocup 230 Volt 154 01 Dual Scale Thermometer with Metal Di...

Page 5: ...3 2 000 Volts Peak Trip Current 61 5 mA Size 9 5 6 5 3 5 24 1 16 5 8 9 cm Weight 2 lbs 15 oz 1 3 kg Shipping Size 11 11 7 28 28 18 cm Shipping Weight 10 lbs 4 54 kg Electrode Housing Material resistan...

Page 6: ...120 F 48 8 C 3 Pour the sample through a 12 mesh screen or Marsh Funnel screen into a glass or plastic container Do not use a metal container Record the mud temperature on the Drilling Mud Report Form...

Page 7: ...andard Again the ES value should be within 2 of the value marked on the standard If either reading is not within the specified range the unit will require ser vice from a trained technician Calibratio...

Page 8: ...ny losses or damages that occur as a result of Improper installation or maintenance of the products Misuse Neglect Adjustment by non authorized sources Improper environment Excessive or inadequate hea...

Reviews: