When a motorized appliance or a tool turns on, there is almost always an initial surge of power to start up.    This surge 
of power is referred to as the "starting load" or "peak load".    Once started, the tool or appliance requires less power to 
operate.    This  is  referred  to  as  the  "Continuous  Load".    This  information  is  usually  stamped  or  printed  on  most 
appliances and equipment or can calculated as per below: 
Multiply: 

AC AMPS 

230 

(AC voltage) = 

WATTS 

 

To determine the current draw from your batteries, you take the 

WATTS

 that you device draws /12 volts to give you the 

DC amps.     
This formula yields a close approximation of the continuous load of your appliance.   
Multiply: 

WATTS 

= Approximate starting load for most appliances   

This formula yields a close approximation of the starting load of most appliances.    Exceptions are motorized appliances 
such as pumps, freezers and air conditioners.    These appliances can have peak startup loads of up to 8 times the rated 
continuous load. 

 

 

FRONT PANEL AND REAR PANEL REPRESENTATION   

(some models will have 1 or 2 x 230v outlets or multiple LCD screens and arrangement may change with model updates over time) 

 
 
 
 
 

 

 

 

 

 

 

 

(300W-1500W) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2000W-6000W) 

4000/8000w 24v model includes AC line terminals for hard wired connections by licensed electricians 

All Pure Sine Wave Models include a 5m remote power control panel with status indicator for remote switching 

 

Summary of Contents for AllSpark PS Series

Page 1: ...AllSpark Inverters USER MANUAL PS Series Pure Sine Wave PI Series Modified Sine Wave Next review date 15 12 19 WELCOME...

Page 2: ...free air circulation around the unit Do not place items on or over the Inverter during operation The unit will automatically shut down if the internal temperature gets too high Restart the Inverter af...

Page 3: ...mps This formula yields a close approximation of the continuous load of your appliance Multiply WATTS X 2 Approximate starting load for most appliances This formula yields a close approximation of the...

Page 4: ...cooling fan automatically turns on to cool the Inverter when the temperature inside the Inverter exceeds the preset limit It turns off when the temperature reduces 12 Charger indicator If LED is lit g...

Page 5: ...unfused cable to the negative black terminal of the battery bank 8 Connect the negative black cable to the Inverter s negative black terminal 9 Insulate the end of cable to be connected to the positi...

Page 6: ...he Inverter off This Inverter has a soft starting function Always wait to turn ON your appliances for a minimum of 3 seconds after powering up the inverter 6 Turn the appliance ON Notes The audible al...

Page 7: ...meter shows the output voltage and battery voltage The battery DC voltage only shows at the startup of the Inverter and when the battery voltage drops to low battery voltage protection level Three LED...

Page 8: ...rranty and contact AllSpark customer service Model PI 300012 PS 250012 PS 500024 Continuous power 2400W 2000W 4000W Maximum power 3000W 2500W 5000W Surge power 4800W 4000W 8000W Output Wave Modified P...

Page 9: ...s of Sale and Privacy Policy can be found on our website at www offroadliving com au These documents outline your rights and obligations under this Warranty and Australian Consumer Law with regards to...

Reviews: