18
E1
05
Control unit failure
Control unit
defective or
wiring defective
Check or replace
operating unit,
check wiring
harness to unit
Digital control has
faulty ID
Switch the generator
off, adjust the DIP-
switches correctly
Control unit faulty
Replace the control
unit
E1
06
Internal temperature
too high
Air routes blocked
Fan clogged,
temperature
sensor defect, close
exterior
heat sources
Clear air routes
Clean fan
E1
07
Coil temperature
Coil temperature
to high
Remove pan, switch
off and wait a
couple of minutes
until the cooking
down
Temperature sensor
faulty
The sensor must be
replaced
E1
08
Mains phase failure
Breakdown of mains
phase or
mains quality
Check mains supply
E1
10
Communication
error
Failure on LIN or
CAN-Bus,
no connection
between
keyboard and
generator
Disconnect from
mains and check
connection
E1
11
Initialisation error
Needless control
unit
connected
Connect control unit
to the correct
control plug
Digital control has
faulty ID
Switch the generator
off, adjust the
DIP-switches
correctly
Failure while
initialising of the
hardware
Just wait, the device
will be reset
approx. every 30
sec.
Summary of Contents for IIS4
Page 1: ...FOR RESIDENTIAL AND PROFESSIONAL USE...
Page 4: ...E Electrical connection Fig A 1 IIS4 INSTALLATION MANUAL 4...
Page 5: ...Fig A 2 IIS8 E Electrical connection 5...
Page 6: ...Fig A 3 IWS4 E Electrical connection 6...
Page 7: ...CONNECTIONS OVERVIEW Fig B 7...
Page 22: ...22...
Page 23: ...23...
Page 24: ...en...