INSTALLATION

• 

The operations for installing, conversions for use with other types of gas and starting up must be done only 

by qualified personnel whose qualifications comply with the norms in force.

• 

Gas installations, the electrical connections and the rooms in which the appliances are installed must comply 

with the norms in force in the Country in which the installation is carried out; above all, the appliance must 

be installed in a well ventilated room, preferably under an extractor hood, so as to ensure the complete 

extraction of gas emissions which are formed during combustion. The air necessary for combustion is 

2m3/h per kW of power installed.

Attention:

 In accordance with international rules, when connecting the appliance, an automatic device enabling the 

disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening 

of at least 3 mm.

CHECKING FOR ADEQUATE VENTILATION

Make sure that the air intake into the room where the appliance is installed is sufficient for an adequate change of air, as 

specified by regulations in effect.

The appliances installed in buildings open to the public must satisfy the following requirements.

Installation rules

The installation and maintenance of the appliance must be done according to the correct procedures and regulation

texts in use, particularly:

• safety standards for the prevention of fire and panic.

Connection and installation of appliance, ventilation and exhaust removal systems, shall be done according to the 

Manufacturer’s instructions and by qualified technicians and according to the regulations in effect. The electric wiring shall 

conform to the regulations in effect. 

All fire prevention codes shall be observed.

a) General indications 

(Rules valid for GB only)

- For all appliances:

Gas safety Regulations, 1984; Health and safety at Work Act, 1974 Codes of Practice, BS 8173, 1982, The Building

Regulations 1985; The Building Standards Regulations, 1981, the IEE Regulations and the by-laws of the local Water 

Undertaking.

The local gas Region or LPG supplier and the local authority and the relevant recommendation of the British Standards 

(latest editions) concerned.

The installation, transformation and repair of appliances for professional kitchens as well as removal due to malfunction, 

and the supply of gas, may be made only by means of a maintenance contract stipulated with an authorized sales office 

and in observance of technical regulations.

The appliance can be installed by itself or in a series side by side with appliances produced by us. 

There must be a minimum distance of at least 10 cm between the appliance and the sides of the nearby cabinets made 

of inflammable material. 

Take suitable measures to guarantee thermal insulation of the inflammable sides, such as, for example, the installation of 

protection against radiation. 

The appliances must be installed in a suitable manner, observing the safety standards. 

The small feet are adjustable to level the appliance.

Summary of Contents for GEFS8P

Page 1: ...GEFS8P RANGE WITH OVEN FOR RESIDENTIAL AND PROFESSIONAL USE INSTRUCTIONS FOR INSTALLATION AND USE...

Page 2: ...le the appliance s maximum power consumption The use of adapters multiple power boards and extension cords is not recommended 8 When not in use switch off the general power supply to the appliance and...

Page 3: ...L DATA TABLE 12 RULES FOR CONVERTING AND INSTALLING OTHER TYPES OF GAS 13 CHANGING THE OPEN RING NOZZLES 13 CHECKING FUNCTIONING 13 MAINTENANCE 13 SPARE PARTS 13 USER MANUAL INSTRUCTIONS FOR USE 14 LI...

Page 4: ...g A 1 GEFS8P 70 cm 73 cm 67 cm 97 cm 90 cm 80 cm 20 cm 3 cm 4 cm 62 cm E 42 cm 10 cm G 1 2 G 1 2 10 cm 40 cm E 80 cm 70 cm Su richiesta accensione con fiamma pilota Also available with pilot flame E L...

Page 5: ...ackofen Bypass By pass four Oven by pass By pass horno FIG F PC GP CF GP FUOCHI FLAMME FEUX COOKING RINGS FUEGOS 562047300M00P00 1 2 3 4 1 Iniettore fuochi Einspritzventil flamme Injecteur feux Inject...

Page 6: ...Officine Gullo 6 ELECTRICAL SCHEME TOP 1 Electrical connection 2 Push button starting burner 3 4 Power station starting burner Fig D...

Page 7: ...AM FAN OVEN 1 Commutator 2 Capacitor 3 Power supply terminal 4 Terminal board switching 5 Engine 6 Element 7 White light 8 Green light 9 Safety thermostat 10 Thermostat Fig I z H 0 6 0 5 N 3 c a V 0 0...

Page 8: ...rticularly concerning room ventilation and discharging gas emissions N B The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect installation alterat...

Page 9: ...ion of fire and panic Connection and installation of appliance ventilation and exhaust removal systems shall be done according to the Manufacturer s instructions and by qualified technicians and accor...

Page 10: ...is supplied without the connection cable to install it proceed in the following way Remove the back panel Push the connection cable through the cable channel connect the conductor wires to the corresp...

Page 11: ...pressure and verify that the description of the nozzle installed corresponds to the one supplied by the manufacturer Connection with natural gas H G20 The connection pressure for natural gas is 20 mb...

Page 12: ...ner injector 1 100 mm Min output adjustment 1 100 mm Consumption Primary air h mm 135 75 kg h 0 591 20 135 75 kg h 0 582 20 205 adjustable m3 st h 0 794 20 Burner max 3 5 kW min 1 15 kW G110 8 mbar G1...

Page 13: ...ight or left until the thermal power reaches 1 15 kW for the 3 5 kW burner 1 55 for the 5 5 kW burner and 2 5 kW for the 7 kW burner Warning If liquid gas is being used the minimum adjustment screw mu...

Page 14: ...few seconds and then released The flame may go out in which case it is necessary to repeat the procedure By turning to the position the burner is brought to the minimum To put out the burner turn the...

Page 15: ...re until the desired effect is achieved The brass details should then be dried Do not use polish as this is suitable for maintaining the gloss but not the antique finish and could result in an effect...

Page 16: ...FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME Turn off the gas tap and clean the appliance as specified above MAINTENANCE only for qualified personnel Any kind of maintenance must onl...

Page 17: ...ctly to the outside is acceptable Forced Discharge Fig 2 but its capacity must not be inferior to what is established in item 4 3 of the UNI CIG norm 8723 In the event of forced discharge The gas supp...

Page 18: ...me in the oven we suggest opting for the lower value in the thermostat adjustment range given in the table Cooking time will be longer if the heat is lower TYPE OF FOOD SLOT NO from the bottom QUANTIT...

Page 19: ...ets steaks cod hake sole 1 3 1 180 30 Mackerel turbot salmon 1 3 1 180 45 Oysters 1 3 1 180 20 Oven bakes Pasta 1 3 2 185 60 Vegetables 1 3 2 185 50 Sweet and savoury souffl s 1 3 0 75 180 50 Pizza an...

Page 20: ...Tel 39 055 656 0324 info officinegullo com Via Della Torricella 29 Antella Bagno a Ripoli 50012 Florence Italy OFFICINEGULLO COM en international V 1 0 7 20...

Reviews: