22
2.6
Operating the inverter/charger
1)
Close the circuit breaker of the battery side.
2)
Turn the rocker switch on the side of the inverter/charger to the ON state. The inverter/charger generally
works when the indicator is ON solid.
WARNING
Ensure that the battery connection is correct and the battery circuit breaker is turned on
first. And then, close the PV array and utility circuit breakers after the inverter/charger
running normally. Again, we won't assume any responsibility for not following the operation.
3)
Close the circuit breaker of the PV array.
4)
Close the circuit breaker of the utility input.
5)
After the AC output is normal, turn on the AC loads one by one. The inverter/charger typically works as per
the set mode. Do not turn on all the loads simultaneously to avoid protection due to a large transient
impulse current.
CAUTION
When supplying power for different AC loads, it is recommended to turn on the load with
a large impulse current. And then turn on the load with a smaller impulse current after
the load output is stable.
If the inverter/charger is not operating correctly or the LCD or the indicator shows an
abnormality, please refer to "Troubleshooting" or contact us.