Instruction manual for installation, maintenance and use
Electric Kettles
- GB -
Page
10 di 19
3.2. INSTRUCTIONS FOR USE
−
Before cooking with the appliance for the first time, wash the interior of the cooking vat thoroughly.
Warning! :
Fill the cooking vat up to a maximum of 40 mm under the overflow border, according
to the maximum level mark, including the food to be cooked.
Warning! :
Before filling the vat, always check that the drainage tap is closed.
3.2.1. FILLING THE JACKET
–
MOD. 100-150LT.
Warning! :
The water level in the jacket must be checked each time before lighting.
Warning! :
It is advisable to use softened water to fill the jacket!
Open the level tap on the front of the appliance.
Unscrew the filling cap on the safety valve unit. The latter is on the right of the appliance surface (see figure
“
Size of appliance and position of connections
”).
Fill with softened water (the capacity of the jacket is
stated in the paragraph “
Technical data
”).
When water flows out of the level tap, close it and screw back on the safety unit cap.
MOD. 200/300/500 LT.
–
170/270/370LT.
Warning! :
The water level in the jacket must be checked each time before lighting.
Warning! :
It is advisable to use softened water to fill the jacket!
−
Open the level tap on the front of the appliance.
−
Unscrew the filling cap on the safety valve unit. The latter is on the right of
the appliance surface (see figure
“
Size of appliance and position of
connections
”).
−
Reposition the tap (an external hole is available) on the external pin of the
relief valve.
−
This operation is required to prevent water bubbles from forming in the
jacket during water loading. Water bubbles would not make it possible to
reach a correct water level in the jacket
.
−
Fill with softened water (the capacity of the jacket is stated in the paragraph “
Technical data
”).
−
When water flows out of the level tap, close it and screw back on the safety unit cap.