P_2 RS485 communication settings

P_2 Nastavení komunikace RS485

Parameter

Parametr

Meaning

Význam

Factory 

settings

Tovární 

nastavení

Setting range

Rozsah nastavení

Id

unique device number in the RS485 network

jediněčné identifikační číslo přístroje v síti RS485

0

0 ÷ 255

bd

communication speed of data transmission

komunikační rychlost přenosu dat

9.6

9.6/19.2/38.4/57.6/115 kBd

PAr

parity

parita

---

--- (none), _o_ (odd), _E_ (even)

--- (žádná), _o_ (lichá), _E_ (sudá)

St

stopbit

stopbit

1

1/2

Prog

5s

Prog

Prog

Prog

Prog

Prog

Prog

Prog

Prog

Prog

Summary of Contents for PAQ-50 Series

Page 1: ...NALYZER ANALYZ TOR PAQ 50 PAQ 51 PAQ 52 INSTRUCTIONS FOR USE N VOD K POU IT Installation service and maintenance of the electrical equipment may be carried out by an authorized person only Mont obsluh...

Page 2: ...ement using current transformers X 5 or X 1 The multifunction network analyzer is designed for monitoring electrical parameters of three phase and single phase LV and MV networks The device design is...

Page 3: ...99 0 999 5 TDD Total demand distortion TDD 0 999 5 Voltage harmonics Pod l vy ch harmonick ch U 0 999 0 999 class 1 Current harmonics Pod l vy ch harmonick ch I 0 999 0 999 class 1 Voltage asymmetry N...

Page 4: ...ion in the menu value increase Pohyb v menu zv en hodnoty ESC to cancel selection exit the menu ESC zru en volby odchod z menu Navigation in the menu value decrease Pohyb v menu sn en hodnoty Active s...

Page 5: ...5 6 7 8 9 10 l k l k l k I1 I2 I3 1 2 3 4 L1 L2 L3 N 16 15 14 13 B RS485 A 24 23 22 21 20 19 R3 R2 R1 25 26 27 28 29 30 COM IN IO4 IO3 IO2 IO1 COM OUT 12 L 11 24VDC AC N 5 6 7 8 9 10 l k l k l k I1 I...

Page 6: ...6 994293 Z00 2 2 4 5 1 3 MOUNTING MONT 6 dimensions rozm ry 88 54 42 6 27 3 5 45 2 62 10 90 2 109 5 88 10 54 42 6 17 5 27 3 5 45 2 62 90 2 109 5 PAQ 50 PAQ 51 PAQ 52...

Page 7: ...ment 0 HQt QDS Wt Current measurement 0 HQt SURXG PAQ 5 U230 PAQ 5 U024 Power supply 1DSiMHQt L1 L2 L3 N k l k l k l N FU F1 FU L1 L2 L3 N PE L K L K L K L k l k l k l 11 12 Power supply 1DSiMHQt N L...

Page 8: ...another device such as an RS485 signal converter to another interface or a master device equipped with a communication gateway P stroj je vybaven galvanicky odd len m komunika n m rozhran m RS485 s p...

Page 9: ...T aktivuje editaci a ukl d nov nastavenou hodnotu Zm na hodnoty je mo n pomoc kurzorov ch kl ves a 6 Nastavte p evodov pom r m ic ho transform toru proudu v parametru Itr Pro zm nu hodnoty pou ijte kl...

Page 10: ...Y year 20 nastaven roku 20 00 09 99 M month setting nastaven m s ce 01 01 12 D day setting nastaven dne 01 01 31 h hour setting nastaven hodiny 00 00 23 M minute setting nastaven minuty 00 00 59 PAS p...

Page 11: ...11 994293 Z00 Prog 5s Prog Prog Prog Prog Prog kV Prog kV Prog kVA Prog kVA Prog Hz kWh Prog kWh Prog Prog Hz...

Page 12: ...12 994293 Z00 Prog Prog Prog Prog Prog Prog Prog Prog Prog Prog Prog Prog Prog Prog Prog...

Page 13: ...ozsah nastaven Id unique device number in the RS485 network jedin n identifika n slo p stroje v s ti RS485 0 0 255 bd communication speed of data transmission komunika n rychlost p enosu dat 9 6 9 6 1...

Page 14: ...irmware maz n energi Parameter Parametr Meaning V znam FIr firmware version information informace o verzi firmware VEr hardware version verze hardware CLr clearing saved tariff energy nulov n po tadla...

Page 15: ...COS phi COS fi Active power LQQ Y NRQ Reactive power Jalov v kon SSDUHQW SRZHU GiQOLY Y NRQ The device is equipped with clear user display with symbols of displayed values for measured quantities For...

Page 16: ...a tes with the meanings described in the following table Signalizace stavu vstup a v stup Vstupy a v stupy se mohou nach zet ve ty ech provozn ch stavech Signalizace na displeji je spole n pro v echny...

Page 17: ...z kladn nastaven p mo pomoc tla tek na p stroji Dal funkce jsou dostupn pouze ze softwaru OEZ PAQ Lze tak p ehledn a jednodu e konfigurovat nastaven nastavovat p esn as definovat parametry komunikace...

Page 18: ...and time zone as a datum Nastaven asu a data z PC a mo nost nastaven p echodu letn ho zimn ho asu a asov z ny RS485 communication Setting RS485 ID baud rate parity stopbit Komunikace RS485 Nastaven I...

Page 19: ...similar to PLC programming Individual logic operations are defined for different function blocks In this universal way it is possible to define functions of e g current relay or more complex three sta...

Page 20: ...stored Consideration should be given to the appropriate storage interval given the potentially large amount of data in the database Z znam hodnot OEZ PAQ umo uje zaznamen vat vybran m en hodnoty v dan...

Page 21: ...s Nastaven tarifu Nastaven ovl d n tarifu pro m en energi Tarif m e b t p ep n n na z klad I O vstupu nebo pomoc asov ch program Modbus registers A detailed description of the Modbus registers is avai...

Page 22: ...stup vstup 3 relays 5 A 250V AC 4 digital I O Type of digital outputs Typ digit ln ch v stup open collector optical separation otev en kolektor optick odd len Max voltage of digital outputs Max nap t...

Page 23: ...pom r m c ho transform toru nap t 1 750 000 Ratio of measuring current transformer P evodov pom r m c ho transform toru proudu 1 10 000 Max number of registered failures Max po et registrovan ch v pa...

Reviews: